Output Indicators
10-10
MS-860 Industrial Raster Reader User’s Manual
Output Indicators
Green Flash Mode
Disabled
Green flash LEDs are disabled.
Good Read (Green Flash)
Green flash LEDs will flash for less than one second when a good read condition is meet
or when matchcode is enabled and a match occurs.
Static Presentation (Green Flash)
Static Presentation is used in conjunction with
Continuous Read mode.
When operating in
Static Presentation mode, whenever the EZ trigger is pressed, the
reader will search for a symbol in
Continuous Read mode. When a symbol is placed in
the FOV and a good read occurs, the green LED will illuminate and stay on for the dura-
tion of time set in
Green Flash Duration.Only one read will occur during that time
unless more than one symbol is enabled in
Number of Symbols.
Note: If Static Presentation mode is selected but the reader is not in Continuous
Read, Green Flash Mode will revert to the default Good Read.
To use Static Presentation:
1. Enable
Continuous Read (see
"Trigger"
on page 3-6).
2. Select the number of symbols (see
"Multisymbol"
on page 7-4).
3. Enable
Static Presentation in Green Flash Mode.
4. Select the read time in
Green Flash Duration (see
"Green Flash Duration"
on
page 10-11).
Usage:
Used as a visual verification that a good read has occurred.
Definition:
A green LED in the front of the reader can be programmed to flash briefly
in response to user-defined conditions, or if in
Static Presentation
mode, illuminate for a set period of time.
Serial Cmd:
<
K750,green flash mode
,[unused],green flash duration>
Default:
Good Read
Options:
0 = Disabled
1 = Good Read
2 = Static Presentation
3 = Match
4 = Mismatch