13-6
MS-4Xi Imager User’s Manual
Counters
Counters
Counter
commands can be a numeric value from
00000
to
65535
. After reaching the
maximum numeric limit of 65535, an error message will be displayed and the counter will
automatically roll over and start counting again at 00000. To obtain the cumulative total of
counts after the rollover has occurred, add 65536 per each rollover (the imager does not
keep track of the number of rollovers) to the current count.
Note:
All counter values will be lost if power is cycled, or if the imager receives a
Reset
or
Save
command.
Click the
Request
button to display the appropriate count or
Clear
to set the counter to zero.
Click the
Utilities
button and then the
Counters
tab to
display the Counters view.
Trigger
,
Good Read
,
No
Read
, and
Mismatch
counters can be
requested and cleared
simultaneously (
Request
All
and
Clear All
buttons)
or individually (
Request
and
Clear
buttons to the
left of each item).
Содержание MS-4Xi
Страница 1: ...MS 4Xi Imager User Manual P N 84 004444 Rev A ...
Страница 12: ...xii MS 4Xi Imager User s Manual Statement of RoHS Compliance ...
Страница 26: ...1 14 MS 4Xi Imager User s Manual Save Configuration in ESP ...
Страница 44: ...2 18 MS 4Xi Imager User s Manual Using EZ Trax ...
Страница 64: ...3 20 MS 4Xi Imager User s Manual Postamble ...
Страница 110: ...5 28 MS 4Xi Imager User s Manual Setting Up the Imager for EZ Trax ...
Страница 152: ...6 42 MS 4Xi Imager User s Manual Background Color ...
Страница 256: ...10 30 MS 4Xi Imager User s Manual Morphological Operation and Operator Size ...
Страница 306: ...13 26 MS 4Xi Imager User s Manual Other Operational Serial Commands ...
Страница 329: ...MS 4Xi Imager User s Manual A 9 Appendices PNP Output for Host Input ...
Страница 330: ...A 10 MS 4Xi Imager User s Manual Communication Protocol Commands PNP Output for External Load ...
Страница 332: ...A 12 MS 4Xi Imager User s Manual Electrical Specifications PNP ...
Страница 333: ...MS 4Xi Imager User s Manual A 13 Appendices Output Wiring ...