MICROPLEX
Operator’s Manual logiJET T4-2 /T6-2 /RFID
Edition 2.2
Parameters:
Each rf command contains one or more type codes. Most of these
type codes are followed by an appropriate parameter.
Permissible values of the rf command parameters <kxxnn> :
Type
code
kxx
Parameter
Description
00
no parameter
allowed
Terminate RFID processing
of the current label (label that is below
the RF Write/Read module of the
printer).
Please refer to the example in figure
10.4.1.a. This command can be used
to teminate RFID processing of label B
in order to cut label A immediately.
Hint: the ID number of label B is
available only if it was read
previously.
01
no parameter
allowed
Read ID
Reads the transponder (label ID
number), the answer is sent to the host
(via the printer SOLID status channel;
ASCII formatted).
11
nn = 2-digit
decimal
Data block number
When writing:
00 = EPC* = default
01 = user
When reading:
nn = block number
12
n = 1-digit
Data format
0 = binary = default
(ASCII presented as they are)
1 = Hex-ASCII
*EPC: Electronic Product Code