4.1.1.3
Mounting to Metric Optical Table (25mm x 25mm spacing)
w
Assuming 25mm optical table hole spacing.
w
Check manufacturing tolerances of the optical table for precision fit.
w
For internal motor configurations: Mounting screws must be flush with base surface.
Travel
A
[mm]
25mm
75
50mm
75
100mm
125
200mm
225
300mm
325
Requires:
2x M2 x 6mm Dowel Pins
4x M3 to M6 Thread Adapters
4x M3 Socket Head Cap Screws
(Low Profile recommended)
1. Move carriage via controller*, if
necessary, to access four
mounting holes. Insert Thread
Adapters and M3 SHCS as shown.
Metric Optical Table Mounting Pattern