2.2 Which values are normal?

Blood pressure is too high if at rest, the diastolic pressure is above 90 mmHg and/or the systolic blood-
pressure is over 160 mmHg. In this case, please consult your doctor immediately. Long-term values at this
level endanger your health due to the associated advancing damage to the blood vessels in your body.
Should the systolic blood-pressure values lie between 140 mmHg and 160 mmHg and/or the diastolic
blood-pressure values lie between 90 mmHg and 95 mmHg, likewise, please consult your doctor. Further-
more, regular self-checks will be necessary.

With blood-pressure values that are too low, i.e. systolic values under 105 mmHg and/or diastolic values
under 60 mmHg, likewise, please consult your doctor.

Even with normal blood-pressure values, a regular self-check with your blood-pressure monitor is recom-
mended. In this way you can detect possible changes in your values early and react appropriately.

If you are undergoing medical treatment to control your blood pressure, please keep a record of the level of
your blood pressure by carrying out regular self-measurements at specific times of the day. Show these va-
lues to your doctor. 

Never use the results of your measurements to alter independently the drug

doses prescribed by your doctor.

Table for classifying blood-pressure values (units mmHG) according to World Health Organization:

Range

Systolic

Diastolic

Measures

Blood-pressure

Blood-pressure

Hypotension

lower than 100

lower than 60

Check with your doctor

Normal range

between 100 and 140

between 60 and 90

Self-check

Mild hypertension

between 140 and 160

between 90 and 100

Consult your doctor

Moderately serious

between 160 and 180

between 100 and 110

Consult your doctor

hypertension
Serious hypertension

higher than 180

higher than 110

Consult your doctor 
immediately

Further information

If your values are mostly standard under resting conditions but exceptionally high under conditions of
physical or psychological stress, it is possible that you are suffering from so-called «labile hypertensi-
on». Please consult your doctor if you suspect that this might be the case.

Correctly measured diastolic blood-pressure values above 120 mmHg require 

immediate medical 

treatment.

2.3. What can be done, if regular increased/low values are obtained?

a)

Please consult your doctor.

b)

Increased blood-pressure values (various forms of hypertension) are associated long- and medium term
with considerable risks to health. This concerns the arterial blood vessels of your body, which are
endangered due to constriction caused by deposits in the vessel walls (Arteriosclerosis). A deficient
supply of blood to important organs (heart, brain, muscles) can be the result. Furthermore, with
long-term continuously increased blood-pressure values, the heart will become structurally damaged.

1.

Introduction

1.1. Features of the BP 3BTO-H

The blood-pressure monitor BP 3BTO-H is a semi-automatic, digital blood-pressure measuring device for
use on the upper arm, which enables very fast and reliable measurement of the systolic and diastolic blood-
pressure as well as the pulse frequency by way of the oscillometric method of measuring.
The device offers a very high and clinical tested measurement accuracy and has been designed to provide a
maximum of user-friendliness.

Thanks to the large LCD display of BP 3BTO-H, both operational status and cuff pressure are visible for the
entire duration of the measurement.

Before using, please read through this instruction manual carefully and then keep it in a safe place. For furt-
her questions on the subject of blood-pressure and its measurement, please contact your doctor.

Attention!
1.2. Important information about self-measurement

Do not forget: 

self-measurement means Control

, not diagnosis or treatment. Unusual values must

always be discussed with your doctor. 

Under no

circumstances should you alter the dosages of any

drugs prescribed by your doctor.

The pulse display is 

not

suitable for checking the frequency of heart pacemakers!

In cases of cardiac irregularity (Arrhythmia), measurements made with this instrument should only be
evaluated after consultation with the doctor.

Electromagnetic interference:

The device contains sensitive electronic components (Microcomputer). Therefore, avoid strong electrical or
electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave cookers). 
These can lead to temporary impairment of the measuring accuracy.

2.

Important information on the subject of blood-pressure and its measurement

2.1. How does high/low blood-pressure arise?

The level of blood-pressure is determined in a part of the brain, the so-called circulatory centre, and
adapted to the respective situation by way of feedback via the nervous system.
To adjust the blood-pressure, the strength and frequency of the heart (Pulse), as well as the width of circu-
latory blood vessels is altered. The latter is effected by way of fine muscles in the blood-vessel walls.
The level of arterial blood-pressure changes periodically during the heart activity: During the «blood ejec-
tion» (Systole) the value is maximal (systolic blood-pressure value), at the end of the heart’s «rest period»
(Diastole) minimal (diastolic blood-pressure value).
The blood-pressure values must lie within certain normal ranges in order to prevent particular diseases.

2

Содержание BP 3BTO-H

Страница 1: ...fe BP 3BTO H Semi automatic Blood Pressure Monitor Instruction Manual 1 13 14 29 P automatyczny ci nieniomierz krwi Instrukcja obs ugi 30 43 F lautomata v rnyom sm r Haszn lati tmutat 44 57 www microl...

Страница 2: ...Czech Republic Tel 420 56 7212 396 Fax 420 56 7212 396 Estonia Oriola AS Estonia Saku tn 8 EE 11314 Tallinn Estonia Tel 372 65 15 100 Fax 372 65 15 111 Greece Cyprus Karabinis ALFA GAUZE Ltd 151 Lavr...

Страница 3: ...deposits in the vessel walls Arteriosclerosis A deficient supply of blood to important organs heart brain muscles can be the result Furthermore with long term continuously increased blood pressure va...

Страница 4: ...n the common primary essential hypertension and secondary hypertension The latter group can be ascribed to specific organic malfunctions Please consult your doctor for information about the possible o...

Страница 5: ...sely to your upper arm Measure always on the same arm normally left Attempt to carry out the measurements regularly at the same time of day since the blood pressure changes during the course of the da...

Страница 6: ...ng position The measurement now proceeds on its own If no measu rement takes place and all that appears in the display is a flashing upwards pointing arrow see below under Inflate further When the ins...

Страница 7: ...and then exchange them for new The pressure does not rise although the Check the connection of the cuff tube and pump is running connect properly if necessary The device frequently fails to measure t...

Страница 8: ...ircumference 22 32 cm cuff type L for arm circumference 32 42 cm Technical alterations reserved 11 www microlife com Detailed user information about our thermometers and blood pressure monitors as wel...

Страница 9: ...15 1 1 1 1 BP 3 1 2 2 2 2 1 K 2 2 K 2 3 3 3 C C 4 4 4 1 4 2 5 5 5 1 5 2 5 3 5 4 5 5 5 6 5 7 6 6 7 7 8 8 9 9 1 10 0 1 11 1 w ww ww w m miic cr ro olliif fe e c co om m...

Страница 10: ...17 1 1 1 1 1 1 B BP P 3 3 x 1 1 2 2 2 2 2 2 1 1 K K 16 2 2 2 2 K K K 90 160 140 160 90 100 K K 110 60 mmHg 3 100 60 100 140 60 90 140 160 90 100 160 180 100 110 180 110...

Страница 11: ...K K 40 3 3 BP 3 K K T M 22 32 L 32 42 19 120 2 2 3 3 K A A Diabetes mellitus 18 AC 1...

Страница 12: ...21 4 4 4 4 1 1 AA 4 316 R6 1 5 1 5 1 2 K K I O 4 4 2 2 1 1 1 20 5 5 5 5 1 1 10 5 5 2 2 K K K 15 10 1 5 5 3 3...

Страница 13: ...23 2 3 2 5 5 4 4 I 2 t 0 22 40 160 180 5 5 5 5 5 5 s 20 300 HI 2 3 cm letku...

Страница 14: ...25 5 5 6 6 5 5 7 7 MEMORY 1 6 6 1 E ER RR R 1 1 20 E ER RR R 2 2 E ER RR R 5 5 15 RWT V Essen 3 sec 24 1 2 1 2 3...

Страница 15: ...27 7 7 26 8 8 BP 3BTO H 9 9 EN1060 1 12 95 EN1060 3 09 97 DIN 58130 NIBP clinical investigation ANSI AAMI SP10 NIBP requirements EN 60601 1 2 K K DIN 58130 1997 6 93 42 EWG IIa...

Страница 16: ...29 1 10 0 265 131 174 73 5 50 C 15 85 10 40 C 30 280 40 200 0 299 1 3 5 40 200 4 316 R6 1 5 K K 22 32 L 32 42 1 11 1 w ww ww w m mi ic cr ro ol li if fe e c co om m www microlife com 28...

Страница 17: ...ci nienia 3 Elementy ci nieniomierza 4 Obs uga ci nieniomierza 4 1 Zak adanie baterii 4 2 Pod czanie w a gumowego 5 Przeprowadzenie pomiaru 5 1 Przed pomiarem 5 2 Najcz stsze r d a b d w 5 3 Zak adani...

Страница 18: ...wnym chorobom warto ci ci nienia musz si mie ci w okre lonych granicach normy 32 33 2 2 Jakie warto ci ci nienia s normalne O zbyt wysokim ci nieniu m wimy w wczas gdy mierzone w spokoju ci nienie roz...

Страница 19: ...arza dotycz cymi przebytych chor b takich jak cukrzyca zaburzenia metabolizmu t uszcz w dna moczanowa Na ogi Rzucenie palenia U ywanie tylko umiarkowanych ilo ci alkoholu Ograniczenie spo ycia kofeiny...

Страница 20: ...arze o 10 mmHg 36 37 Mankiety kt re s zbyt w skie lub zbyt kr tkie prowadz do uzyskania niewiarygodnych wynik w Dob r w a ciwego mankietu jest wi c bardzo wa ny Rozmiar mankietu zale y od obwodu ramie...

Страница 21: ...jawia si na ekranie symbol serca i s ycha pisz cz cy sygna pojawiaj cy si przy ka dym uderzeniu serca 38 39 e Po zako czeniu pomiaru s ycha d ugi sygna Mo na teraz wypu ci powietrze z mankietu przez n...

Страница 22: ...Dalsze wskaz wki Poziom ci nienia krwi podlega wahaniom nawet u zdrowych os b Dlatego nale y pami ta e por wnywane pomiary wymagaj zawsze takich samych warunk w spokoju Je li jednak przy zastosowaniu...

Страница 23: ...on przez dystrybutora Nazwa i adres dystrybutora 42 43 9 Standardy Standard aparatu Aparat odpowiada wymogom standardu europejskiego dla ci nieniomierzy nieinwazyjnych EN1060 1 12 95 EN1060 3 09 97 DI...

Страница 24: ...a lland an magas vagy alacsony a v rnyom sa 3 A v rnyom sm r k sz l k k l nb z r szei 4 A v rnyom sm r k sz l k zembe helyez se 4 1 Az elemek behelyez se 4 2 A mandzsetta vezet k csatlakoztat sa 5 A m...

Страница 25: ...onzul t ljon orvos val Ha a v rnyom sa huzamos ideig ilyen magas ez vesz lyeztetheti az eg szs g t mivel a testben l v v red nyek k rosod s hoz vezethet 46 Ha a szisztol s rt k 140 s 160 Hgmm k z tt v...

Страница 26: ...z al bbi bra a BP 3BTO H t pus v rnyom sm r k sz l k r szeit mutatja be a M r eszk z 48 b Mandzsetta opci M m ret 22 32 cm es karker letre L m ret 32 42 cm es karker letre k l nleges tartoz kk nt megv...

Страница 27: ...al bb h rom percig felemelve kell tartani hogy elfolyj on az sszegy lt v r 5 3 A mandzsetta el k sz t se a A mandzsetta v g t vezesse t a levarrt gumi v g vel a f m kengyelen kereszt l gy hogy hurkot...

Страница 28: ...r s le ll t sa Ha b rmilyen okn l fogva pl ha a beteg rosszul rzi mag t nyomja meg a pump n tal lhat leereszt sze lep gombj t Ekkor a nyom s azonnal cs kkeni kezd a mandzsett ban 52 5 7 Mem ria funkc...

Страница 29: ...egyes k sz l kben s ezeket ugyan gy klinikailag tesztelj k A k sz l k gy rt ja elfogadja s a k sz l k maga megfelel a v rnyom sm r k sz l kek eur pai szabv ny gyi el r sainak lsd a technikai adatokat...

Страница 30: ...131 x 174 x 73 mm T rol si h m rs klet 5 s 50 C k z tt P ratartalom 15 85 relat v p ratartalom zemeletet si h m rs klet 10 s 40 C k z tt Kijelz Folyad kkrist lyos LCD M r si m d Oszcillometrikus Nyom...

Отзывы: