MicroHeat MH 6 Series Скачать руководство пользователя страница 8

Page of 17

|      INSTALLATION MANUAL for CFEWH SERIES 6-13      |      V01 - 12 / 02 / 2021

Please read through this section before commencing 

installation to ensure you are familiar with all of the 

component parts and the fitting procedure.

THIS UNIT MUST BE INSTALLED BY:

A LICENSED ELECTRICIAN

 

to ensure installation 

conforms to all current electrical wiring codes and safety 

standards.

A LICENSED PLUMBER

 

to ensure installation conforms 

to all current plumbing codes and safety standards.

OTHER SPECIFICATIONS:

IP RATING

The unit is rated as IP25. The unit must be installed inside 

a dwelling or construction and should not be exposed to 

splashing water, rain or any circumstance that will allow 

water to enter the outside cover.

MAXIMUM RATED OPERATING WATER PRESSURE

The maximum operating water pressure is 

0.8 MPa / 8 bar / 116 PSI.

AMBIENT TEMPERATURE

The unit is intended for internal installation and should not 

be installed in an environment where there is a possibility 

of the ambient temperature dropping below 41°F.

WATER RESISTIVITY

To ensure optimal operation, the resistivity of the 

incoming cold water supply should not be less than 

1.25kΩ-cm, and should not be greater than 7.7kΩ-cm. 

If the unit is operated with water conductivities outside of 

this range, it will not function as specified.

The CFEWH should preferably be installed in a vertical 

position on an internal wall, or in an internal cupboard or 

space. If the safety rules or the instructions outlined in 

this manual are not followed correctly, the unit may not 

operate properly, and could cause damage to property, 

serious bodily injury, and/or death.

MicroHeat, nor its Distributors, will be liable for any 

damages due to failure to comply with the installation and 

operating instructions outlined in this manual or through 

improper use. Improper use includes the use of this unit 

to heat any liquid — other than potable water   — within 

the conductivity range specified in this manual.

o

o

o

o

o

o

o

PRE-INSTALLATION CHECKLIST

 WARNING:

This appliance can be set from 60°F up to 140°F 

in 1°F increments. Water temperatures greater 

than 120°F can cause scalding. Care should 

be taken with children and people with limited 

sensory, physical, and/or mental capability.

 IMPORTANT: 

Failure to comply with the installation and 

operating instructions, or improper use, voids the 

warranty. Never remove the unit cover unless the 

electricity is turned off at the isolation switch or 

switchboard. To reduce the risk of electric shock 

or injury to persons or property, please follow the 

installation instructions carefully.

Where the ambient temperatures are likely to 

approach freezing, i.e., less than 41°F, the unit 

must be drained of water to prevent frozen water 

damage occurring.

For supply connections, use 6AWG or larger 

wires suitable for at least 167°F.

For use on an individual branch circuit only.

 IMPORTANT: 

Supply this appliance only from a grounded 

system. A green terminal (or a wire connector 

marked “G”, “GR”, “GROUND”, OR 

“GROUNDING”) is provided for wiring the 

appliance. To reduce the risk of electric shock, 

connect this terminal or connector to the 

grounding terminal of the electric service or 

supply panel with a continuous copper wire in 

accordance with the electrical installation code.

CAUTION: DO NOT INSTALL IN A BATH 

ENCLOSURE OR SHOWER STALL, OR 

CONNECT TO A SALT-REGENERATED WATER 

SOFTENER OR A WATER SUPPLY OF SALT 

WATER.

Failure to comply with the installation and 

operating instructions, or improper use, voids the 

warranty.

Содержание MH 6 Series

Страница 1: ...LOW ELECTRIC WATER HEATER CFEWH SERIES 6 13 SINGLE PHASE USA INSTALLATION OPERATION MANUAL LEARN MORE AT MICROHEAT US INFO OR SCAN CODE NEXT GENERATION MOLECULAR HEAT TECHNOLOGY ON DEMAND FLOW ADVANCE...

Страница 2: ...Dimensions 4 Speci cations 5 Pre Installation Checklist 6 Installation Overview 7 Electrical Installation BY A LICENSED ELECTRICIAN ONLY 8 10 Plumbing Installation BY A LICENSED PLUMBER ONLY 11 Prepar...

Страница 3: ...ES 6 13 Units include displays showing output water temperature settable up to 140 F temperatures below 120 F are recommended to prevent scalding and flow rate Please ensure you read through the Pre I...

Страница 4: ...CFEWH Electrical Supply Optimized Energy Accurate Heated Water Temperature Optimized Tandem Capability Optimized energy is the capacity to heat water more efficiently delivering reductions in the con...

Страница 5: ...drained of water to prevent frozen water damage from occurring Failure to comply with the installation and operating instructions or improper use voids the warranty Here are some suggested options for...

Страница 6: ...atchel Wall Mounting Screws NOT INCLUDED Inlet Filter PCBA Terminal Block Electric Mains Supply Cable Gland RED GREEN LED GREEN Ready RED Error Flow Rate Temperature Setting Display Exterior Cover Plu...

Страница 7: ...Optimized Direct Energy Transfer Full Digitally Controlled Water Heating Nominal Capacity gallons 0 1 gallons 2 x 0 1 gallons STANDARDS Electrical Safety UL 499 Ed 14 EMC FCC IP Rating IP25 HOT WATER...

Страница 8: ...will be liable for any damages due to failure to comply with the installation and operating instructions outlined in this manual or through improper use Improper use includes the use of this unit to h...

Страница 9: ...Once active wires are connected to the unit the unit must be mounted into position and tested for connectivity The unit hot water outlet is connected to a hot water plumbing fixture and the cold wate...

Страница 10: ...s usually more than one Diversity Factor sum of total demands maximum demand on feeder DEMAND FACTOR Demand Factor is the ratio of the sum of the maximum demand of a system or part of a system to the...

Страница 11: ...AINS SUPPLY CABLE GLAND PRINTED CIRCUIT BOARD ASSEMBLY PCBA V7 4 DISPLAY PCBA PLUG LED INDICATOR PCBA RESET BUTTON PCBA TERMINAL BLOCK L1 L2 ELECTRICAL INSTALLATION TANDEM INSTALLATION With tandem ins...

Страница 12: ...imum diameter of 5 16 will damage the mounting base and crack the body VOIDING THE WARRANTY The unit should be mounted onto a solid internal wall or in an internal cupboard or space capable of continu...

Страница 13: ...ITING VALVE 5 bar 500 kpa SHUTOFF VALVE MUST NOT BE A NON RETURN TYPE VALVE INLET HOT WATER OUT OUTLET LESS THAN 250mm SINGLE CFEWH SERIES 6 13 PLUMBING CONNECTION TANDEM CFEWH SERIES 6 13 x 2 PLUMBIN...

Страница 14: ...thout incurring power overshoot Once primed the unit will ramp up to the optimized power required at the time without overshoot NOTE Power overshoot typically results from the maximum power input requ...

Страница 15: ...120 116 113 110 107 105 102 98 96 OPTIMIZED ENERGY USAGE kW 3 1 4 2 5 2 6 3 7 3 8 4 9 4 10 5 11 5 12 6 13 0 13 0 13 0 13 0 13 0 13 0 13 0 13 0 13 0 80 F INPUT WATER TEMPERATURE WARM WATER FLOW RATE gp...

Страница 16: ...The 16 LED indicator on the 10 Exterior Cover indicates the operational status of the unit LED INDICATOR NOT ILLUMINATED No electricity is being supplied to the unit SLOW FLASHING GREEN Standby mode...

Страница 17: ...t point Blocking Resolving RED Flashing A 7 Inlet cold water input sensor open circuit Blocking Resolving RED Flashing A 8 Inlet cold water input sensor short circuit Blocking Resolving RED Flashing A...

Страница 18: ...connect the connecting cable from the 19 PCBA Plug and replace the 10 Exterior Cover MAINTENANCE The unit is designed to provide long and reliable service Actual life expectancy will vary with water q...

Страница 19: ...eat CFEWH literature PROCEDURE FOR HONORING WARRANTY 1 To initiate a claim for a warranty against defects the consumer shall return product to place of purchase for replacement For additional product...

Страница 20: ...ty Ltd 20 Pickering Road Mulgrave VIC 3170 Australia DISTRIBUTED BY JVIS USA LCC 52048 Shelby Parkway Shelby Charter Township MI 48315 Please contact our customer service at support microheat us Micro...

Отзывы: