MicroHeat MH 6 Series Скачать руководство пользователя страница 19

Page 17 of 17

|      INSTALLATION MANUAL for CFEWH SERIES 6-13      |      V01 - 12 / 02 / 2021

LIMITED WARRANTY FOR MH SERIES 6

LIMITED WARRANTY FOR MICROHEAT TECHNOLOGIES PTY LTD 

CONTINUOUS FLOW ELECTRIC HOT WATER HEATER (CFEWH) SERIES.

For the MicroHeat Technologies Pty Ltd Continuous Flow Electric Water Heater SERIES 

(“CFEWH”), MicroHeat US will replace the CFEWH, which falls within the Warranty Periods and 

Territory specified below, subject to the warranty conditions and the warranty exclusions.

Limited Warranty Period within the Territory (United States) is 2 years from the date of purchase 

by the consumer. You are entitled to a replacement for a major failure. It is the responsibility of 

the consumer to provide proof of purchase within the Territory.

WARRANTY CONDITIONS

1. This warranty is applicable only for CFEWH appliances.

2. The CFEWH must be installed in accordance with the MicroHeat CFEWH Installation 

Instructions, to be supplied with the CFEWH water heater, and in accordance with all relevant 

statutory and local requirements of the Country or State in which the CFEWH is installed.

3. Where a CFEWH is replaced under warranty, the balance of the original warranty period will 

remain effective. The CFEWH does not carry a new warranty.

4. Where a CFEWH is replaced under warranty, MicroHeat will provide replacement at 

its expense. Customer is responsible for return of CFEWH to place of purchase when 

replacement is permitted under this warranty. 

5. The warranty only applies to the CFEWH and therefore does not cover any plumbing or 

electrical parts supplied by others and not an integral part of the CFEWH, e.g., pressure 

limiting valve; tempering valves; isolation valves; shut off valves; electrical switches; electrical 

cabling; pumps or fuse.

6. The benefits of this warranty are the sole warranties made by MicroHeat. ALL OTHER 

WARRANTIES, RIGHTS, AND REMEDIES OF THE CONSUMER ARE EXCLUDED EXCEPT 

TO THE EXTENT REQUIRED TO BE PROVIDED UNDER APPLICABLE FEDERAL OR STATE 

LAW. ANY REQUIRED IMPLIED WARRANTIES ARE LIMITED TO A 2 YEAR DURATION. 

7. The CFEWH must be sized to supply the hot water in accordance with the guidelines in the 

MicroHeat CFEWH literature.

PROCEDURE FOR HONORING WARRANTY

1. To initiate a claim for a warranty against defects, the consumer shall return product to place 

of purchase for replacement. For additional product information consumer may contact:

   

MicroHeat US / JVIS USA LLC

   

52048 Shelby Pkwy

   

Shelby Charter Township, MI 48315 

WARRANTY EXCLUSIONS

Replacement will be carried out as set out in the MicroHeat warranty. However, the following 

exclusions may cause the MicroHeat warranty to become void:

1. Accidental damage to the CFEWH or any component, including: acts of God; failure due 

to misuse, abuse, fire or flood damage; incorrect installation; damage as the result of 

transportation, removal or storage; faulty attempts to repair the CFEWH. 

2. Where the complaint is related to circumstances where there is no flow of hot water due to 

faulty plumbing; where water leaks are related to plumbing and not the CFEWH or CFEWH 

components; where there is a failure of electricity or water supplies; where the supply of 

electricity or water does not comply with relevant standards.

3. Where the CFEWH or CFEWH component has failed directly or indirectly as a result of 

excessive water pressure in excess of 8 bar; incorrect pressure limiting valves; incorrect 

tempering valve settings; temperature input in excess of 60ºC /140ºF and/or excessive 

thermal input; blocked outlet; corrosive atmosphere; foreign matter in the water supply; or ice 

formation in the pipe work to or from the CFEWH water heater.

4. Where the CFEWH is located in a position that does not comply with the MicroHeat CFEWH 

Installation Instructions or relevant statutory requirements. 

5. Replacement of the CFEWH due to the effects of either corrosive water or water with a high 

chloride or low pH level caused by unnatural circumstances or when the CFEWH has been 

connected to a water supply with water conductivity levels that are outside the range of 

water conductivity outlined in the Installation Instruction Manual.

This warranty excludes any and all claims for damage to furniture, carpets, walls, foundations, 

or any other consequential loss either directly or indirectly due to leakage from the water heater, 

or due to leakage from fittings and/or pipe work of metal, plastic or other materials caused by 

water temperature, workmanship, or other.

MAINTENANCE HISTORY

(SERVICE TYPE AND DATE)

Содержание MH 6 Series

Страница 1: ...LOW ELECTRIC WATER HEATER CFEWH SERIES 6 13 SINGLE PHASE USA INSTALLATION OPERATION MANUAL LEARN MORE AT MICROHEAT US INFO OR SCAN CODE NEXT GENERATION MOLECULAR HEAT TECHNOLOGY ON DEMAND FLOW ADVANCE...

Страница 2: ...Dimensions 4 Speci cations 5 Pre Installation Checklist 6 Installation Overview 7 Electrical Installation BY A LICENSED ELECTRICIAN ONLY 8 10 Plumbing Installation BY A LICENSED PLUMBER ONLY 11 Prepar...

Страница 3: ...ES 6 13 Units include displays showing output water temperature settable up to 140 F temperatures below 120 F are recommended to prevent scalding and flow rate Please ensure you read through the Pre I...

Страница 4: ...CFEWH Electrical Supply Optimized Energy Accurate Heated Water Temperature Optimized Tandem Capability Optimized energy is the capacity to heat water more efficiently delivering reductions in the con...

Страница 5: ...drained of water to prevent frozen water damage from occurring Failure to comply with the installation and operating instructions or improper use voids the warranty Here are some suggested options for...

Страница 6: ...atchel Wall Mounting Screws NOT INCLUDED Inlet Filter PCBA Terminal Block Electric Mains Supply Cable Gland RED GREEN LED GREEN Ready RED Error Flow Rate Temperature Setting Display Exterior Cover Plu...

Страница 7: ...Optimized Direct Energy Transfer Full Digitally Controlled Water Heating Nominal Capacity gallons 0 1 gallons 2 x 0 1 gallons STANDARDS Electrical Safety UL 499 Ed 14 EMC FCC IP Rating IP25 HOT WATER...

Страница 8: ...will be liable for any damages due to failure to comply with the installation and operating instructions outlined in this manual or through improper use Improper use includes the use of this unit to h...

Страница 9: ...Once active wires are connected to the unit the unit must be mounted into position and tested for connectivity The unit hot water outlet is connected to a hot water plumbing fixture and the cold wate...

Страница 10: ...s usually more than one Diversity Factor sum of total demands maximum demand on feeder DEMAND FACTOR Demand Factor is the ratio of the sum of the maximum demand of a system or part of a system to the...

Страница 11: ...AINS SUPPLY CABLE GLAND PRINTED CIRCUIT BOARD ASSEMBLY PCBA V7 4 DISPLAY PCBA PLUG LED INDICATOR PCBA RESET BUTTON PCBA TERMINAL BLOCK L1 L2 ELECTRICAL INSTALLATION TANDEM INSTALLATION With tandem ins...

Страница 12: ...imum diameter of 5 16 will damage the mounting base and crack the body VOIDING THE WARRANTY The unit should be mounted onto a solid internal wall or in an internal cupboard or space capable of continu...

Страница 13: ...ITING VALVE 5 bar 500 kpa SHUTOFF VALVE MUST NOT BE A NON RETURN TYPE VALVE INLET HOT WATER OUT OUTLET LESS THAN 250mm SINGLE CFEWH SERIES 6 13 PLUMBING CONNECTION TANDEM CFEWH SERIES 6 13 x 2 PLUMBIN...

Страница 14: ...thout incurring power overshoot Once primed the unit will ramp up to the optimized power required at the time without overshoot NOTE Power overshoot typically results from the maximum power input requ...

Страница 15: ...120 116 113 110 107 105 102 98 96 OPTIMIZED ENERGY USAGE kW 3 1 4 2 5 2 6 3 7 3 8 4 9 4 10 5 11 5 12 6 13 0 13 0 13 0 13 0 13 0 13 0 13 0 13 0 13 0 80 F INPUT WATER TEMPERATURE WARM WATER FLOW RATE gp...

Страница 16: ...The 16 LED indicator on the 10 Exterior Cover indicates the operational status of the unit LED INDICATOR NOT ILLUMINATED No electricity is being supplied to the unit SLOW FLASHING GREEN Standby mode...

Страница 17: ...t point Blocking Resolving RED Flashing A 7 Inlet cold water input sensor open circuit Blocking Resolving RED Flashing A 8 Inlet cold water input sensor short circuit Blocking Resolving RED Flashing A...

Страница 18: ...connect the connecting cable from the 19 PCBA Plug and replace the 10 Exterior Cover MAINTENANCE The unit is designed to provide long and reliable service Actual life expectancy will vary with water q...

Страница 19: ...eat CFEWH literature PROCEDURE FOR HONORING WARRANTY 1 To initiate a claim for a warranty against defects the consumer shall return product to place of purchase for replacement For additional product...

Страница 20: ...ty Ltd 20 Pickering Road Mulgrave VIC 3170 Australia DISTRIBUTED BY JVIS USA LCC 52048 Shelby Parkway Shelby Charter Township MI 48315 Please contact our customer service at support microheat us Micro...

Отзывы: