2.3.1
Configuring the Master (Con
’
t)
✓
Configure the pMDDL5824 as a Master
2.0
Quick Start
If any additional
settings need to be
changed, ensure they
are also changed on
the Slave.
Select
Master
from the
Operation
Mode
dropdown box.
Set a
Network ID
, which will need
to be the same on each unit in the
network. This example uses
TEST_ID.
Select
Wireless
from the top/main navi-
gation, and then
RF
from the submenu
list.
For bench or close proximity testing
it is best to use a lower power setting
to prevent RF saturation. Select
20dBm from the
TX Power
setting.
The remaining settings in the
Wireless
menu
should be left as defaults for this exercise.
Refer to
Section 5.3
Wireless
for additional
information.
Click on the
Submit
button to write the
changes to the pMDDL5824. The
Cancel
but-
ton will revert back to previously saved val-
ues
In the RF Configuration ensure the
Compatibility Mode
,
Channel
Bandwidth
and
Channel
-
Frequency
are set the same on each
module.