5.0 Network Topologies
Insofar as the factory defaults are concerned, the difference between the PMP Master and
PMP Slave (above) are simply the Operating Mode (S101), Unit Address (S105), and the Des-
tination Address (S140).
With the exception of the Master modem, all modems in a PMP network have a Destination
Address of 1 - the UA of Master modem - to which all data is destined.
The settings for a factory default PMP Repeater are unique only with respect to S101 (1) and
S105 (3).
Image 5-4: &F2 PMP Slave Configuration View
Each modem in any
network must have a
unique Unit Address.
When bench testing
PMP and using the
factory default settings
for
the
Master,
Repeater, and Slave:
Master S141 must be
changed from 0 to 1,
and Slave S118 must
be modified to be the
UA of the Repeater
(3),
otherwise
the
Slave will synchronize
directly to the Master,
bypassing
the
Repeater.