background image

 

 

 

Microframe Corporation 

 

 

 

 

 

 

 

8

 

604 South 12

th

 Street 

Broken Arrow, OK  74012 
800-635-3811 
www.microframecorp.com 

 

 

 

 

 

 

Series 6300XXX8 

 

Set Display to Timer Mode 

Count UP Timer: Using the remote control, press [MENU] "211" [ENTER]. The display is now in Count UP 
Timer mode. 
Count DOWN Timer: Using the remote control, press [MENU] "212" [ENTER]. The display is now in Count 
DOWN Timer mode. 
 

Operation 

To control the timer with the remote control: 

 

Count UP Mode 
[Up] button to Start / Stop count up  
[Down] button to temporarily countdown  
[Clear]  button to reset to '0'  

 

Count DOWN Mode 
[Down] button to Start / Stop countdown  
[Up] button to temporarily count up  
[Clear] button to reload default time 

 
To control the timer with the push buttons, you must first change the default function of the push buttons.  
See options 6.1 and 6.2 in the Options Definitions. 

 

Count UP Mode 
[Input 1] push button to Start / Stop count up  
[Input 2] push button to reset to ‘0’ 

 

Count DOWN Mode 
[Input 1] push button to Start / Stop count down 
[Input 2] push button to reload default time 
 

Set the Time 

Using  the  remote  control,  type  in  the  new  time  and  press  [ENTER].    If  days  are  not  desired,  press 
[ENTER] again.  If days are desired, type in the days and press [ENTER].  If the display is running, it will 
continue to count up or down. 
 

Set the Reload Time 

Using the remote control, press [MENU] "13" [ENTER].  Type in the desired time and press [ENTER]. 
 

Set the Chime Time 

The display can chime at two chime times, denoted as Chime Times 1 and 2.  In addition, the display can 
chime on zero.  If the display format is set to "Interval," then this number entry will be by the Interval Unit 
"2.4" instead of time format. 

 

Chime Time 1 
Using the remote control, press [MENU] 

“14” [ENTER].  Type in the desired chime time. You may 

optionally specify a specific day to chime on, or leave it blank to chime every day.  Press [ENTER] 
to accept changes. 

 

Chime Time 2 
Using the remote control, press [MENU] 

“15” [ENTER].  Follow the same steps as for chime 1. 

Count UP / DOWN Timer Detailed Instructions 

This  is  used  to  time  an  event,  and  can  show  the  time  to  1/100th  of  a 
second. 

Содержание 6300 8 Series

Страница 1: ...orporation 604 South 12th Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 Website www microframecorp com E mail support microframecorp com SERIES 6300XXX8 INSTALLATION SPECIFICATION GUIDE Revision Date 11 2018 Control 1 1 ...

Страница 2: ...ng used for air return you must use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life suppor...

Страница 3: ...4 Using Your Remote or Push Buttons 5 Quick Settings 6 Clock Detailed Instructions 7 Count Up Down Timer Detailed Instructions 8 Counter Detailed Instructions 10 Takt Time Detailed Instructions 11 Slave Display Options 12 Setting the Programmable Options 13 Options Table Summary 14 Options Definitions 15 Appendix 21 Wiring Diagram 22 General Troubleshooting Chart 23 6300XXX8 Specifications 24 6300...

Страница 4: ...s located on the back of the display Step 2 Connecting Power To connect power to the 24VAC terminal on the display first loosen the terminal s two screws Then push one of the stripped ends of the power adapter wire into each opening in the side of the terminal Tighten each screw onto each wire Check that each wire is secure in each terminal by lightly pulling on it To connect the power adapter wir...

Страница 5: ...may be hung on a wall like a picture For this purpose you will find a keyhole mounting hole on the back of the display Step 5 Powering the Display Plug the power adapter into an AC outlet The display should illuminate and show numeric characters The display ships from the factory in clock mode Using the Remote Please note that the Microframe Remote is specifically designed to work with your displa...

Страница 6: ... the time or count 4 Press UP or DOWN to START or STOP the timer Unit Counter See Counter Detailed Instructions for more information This is used to count the number of contact closures occurring at Input 1 1 Using the remote control press MENU 167 ENTER 2 Type the number followed by ENTER to set count 3 Press UP to increment or DOWN to decrement Takt Timer See Takt Time Detailed Instructions for ...

Страница 7: ... following options apply to the clock mode See Options Definitions for more information 1 1 Current Time 1 2 Current Date 1 4 Chime Time 1 1 5 Chime Time 2 2 2 Clock Format 2 3 Display Format 2 3 0 As time 2 3 2 As date 3 1 Internal Chime 3 2 External Chime 3 3 Chime Volume 4 1 Smallest Time Unit Displayed STU 4 2 Largest Time Unit Displayed LTU 4 3 Leading Zero Suppression 4 4 Colon Flash Rate 6 ...

Страница 8: ...Mode Input 1 push button to Start Stop count down Input 2 push button to reload default time Set the Time Using the remote control type in the new time and press ENTER If days are not desired press ENTER again If days are desired type in the days and press ENTER If the display is running it will continue to count up or down Set the Reload Time Using the remote control press MENU 13 ENTER Type in t...

Страница 9: ...al 1 4 Chime 1 Time Interval 1 5 Chime 2 Time Interval 2 3 Display Format 2 3 0 As time 2 3 1 As Specified Interval 2 4 Interval Unit 3 1 Internal Chime 3 2 External Chime 3 3 Chime Volume 4 1 Smallest Time Unit Displayed STU 4 2 Largest Time Unit Displayed LTU 4 3 Leading Zero Suppression 4 4 Colon Flash Rate 5 1 On Rollover 5 2 On Zero 5 3 Chime on Zero 6 1 Input 1 Action 6 2 Input 2 Action 6 3 ...

Страница 10: ...t by one Input 2 to decrement the count by one Set a New Count Using the remote control type in the new number and press ENTER Fast Inputs For events faster than 10 items per second use Option 6 6 1 Options The following options apply to the counter mode See Options Definitions for more information 2 3 Display Format 2 3 3 As count 6 1 Input 1 Action 6 1 1 Up 6 1 2 Down 6 1 4 Reset 6 2 Input 2 Act...

Страница 11: ...nning it will continue to increment Changing the Takt Interval The Takt interval may be changed as previously noted The last Takt interval may need to complete before the new interval is loaded To apply the new interval immediately reset the Takt timer Battery Backup During a power outage the current Takt number will be preserved The Takt timer will not continue to run except that it will complete...

Страница 12: ...slave displays separately Power runs to multiple displays are limited by the distance required and the number of displays powered Communication runs can be up to 3000 ft long While slaves show the same information as the master they can reformat the data to appear differently than the master For instance for a count up timer three 4 digit displays could be used to display everything from days down...

Страница 13: ...lowed by ENTER Next type in up to six digits of the value representing the time or date followed by ENTER e g if setting time to 3 00 type 300 ENTER Subsection 1 6 is a special Quick Set section It is actually not a memory area at all but a function that sets all other memory areas to a factory Default condition For instance if you want to set all memory areas to what Microframe considers normal f...

Страница 14: ...al Chime 3 3 0 Off 3 3 1 1 Soft 3 3 2 2 3 3 3 3 3 3 4 4 3 3 5 5 3 3 6 6 3 3 7 7 Loud 3 3 8 8 3 3 9 9 Loudest 4 Display 4 1 STU Range Lock 4 1 0 Hundredths of seconds 4 1 1 Seconds 4 1 2 Minutes 4 1 3 Hours 4 1 4 Days 00 99 4 1 5 Days 0100 9999 4 2 LTU Range Lock 4 2 0 Hundredths of seconds 4 2 1 Seconds 4 2 2 Minutes 4 2 3 Hours 4 2 4 Days 00 99 4 2 5 Days 0100 9999 4 3 Leading Zeroes 4 3 0 Show 4...

Страница 15: ...DDDD ENTER Interval format 2 3 1 NNNNNN ENTER HH hours MM minutes SS seconds DDDD days N quantity of the set interval unit This option also serves as the Takt time interval Prompt TAKT time 2 1 5 HH MM SS ENTER DDDD ENTER HH hours MM minutes SS seconds DDDD days If you wish to set hundredths of seconds for the reload time first change the display mode to interval 2 3 1 and the interval unit to hun...

Страница 16: ...f the time that does not fit on the master display 1 6 4 Count Up Time from 0 00 Sets a timer to start counting up from zero 1 6 5 Countdown Time 1 hour Sets a timer to start counting down from 1 hour 1 6 6 Countdown Interval 90 minutes Sets a timer to countdown 90 by minute intervals 1 6 7 Unit Counter Sets a unit counter so that input pulses can be counted from Input 1 or Input 2 1 6 8 Takt Time...

Страница 17: ...ow the date if the master is also showing the date 2 3 0 As time Show in standard time format DDDD HH MM SS hh hundredths of a second Max 9999 23 59 59 99 Applies to 2 1 0 2 1 1 2 1 2 2 1 3 2 3 1 As specified interval Show by the interval specified in 2 4 Max 65535 days 999999 all other units Applies to 2 1 1 2 1 2 2 1 3 2 3 2 As date Show the date Applies to 2 1 0 2 1 3 2 3 3 As count Show the cu...

Страница 18: ...e a 4 digit display show hours and minutes never seconds set this value to 3 4 3 Leading Zeros Shows or hides the leading zeros for timers Unit Counter and Takt time modes always suppress the leading zeroes 4 4 Colon Flash Rate Determines how fast the colons flash while the timer is running 4 5 Size This is the display s factory set number of digits A four digit display is indicated by a 4 This op...

Страница 19: ...6 1 2 Start Starts Timer 6 1 3 Start Stop Alternately starts and stops timer 6 1 4 Reset Resets timer 6 1 5 Stop Reset Stops Timer and Resets it 6 1 6 Reset Start Resets Timer and Starts it 6 1 7 Start Stop Reset Alternately starts and stops timer resetting each time 6 1 8 One Button Mode 1st press starts timer 2nd press stops timer 3rd press performs Input 2 Action 6 2 Input 2 Action Determines w...

Страница 20: ...from open to closed 6 5 1 Change of State Expects a toggling closure at Inputs 1 and 2 For example an on off switch Responds any time the input changes from open to closed or closed to open 6 6 Button Debounce Ignores noise on Inputs 1 2 During a single press buttons can bounce many times This results in additional button presses that the user did not intend This option ignores the additional butt...

Страница 21: ...Microframe Corporation 21 604 South 12th Street Broken Arrow OK 74012 800 635 3811 www microframecorp com Series 6300XXX8 SERIES 6300XXX8 APPENDIX ...

Страница 22: ...Microframe Corporation 22 604 South 12th Street Broken Arrow OK 74012 800 635 3811 www microframecorp com Series 6300XXX8 Wiring Diagram ...

Страница 23: ...lightning strikes CallMicroframetoreceiveanRMA and then return to factory for repair Different displays are showing different numbers or times Poor signal connection to master display or displays are in different modes Check signal cables and routing Make sure A and B wires are not reversed Check Programmable Options to make sure correct modes are selected Display is not showing expected time desp...

Страница 24: ...ase option Display Size 4 Digit 6 Digit Power Requirements Watts 100 bright 29 7 W 43 0 W Current 12VDC 2 48A 3 58A Current 24VAC 1 24A 1 79A Weight 6 0 lbs 8 1 lbs Width A Dimension Inches Centimeters 21 3 54 1 31 1 79 0 Model 6300AXX8 Specifications Features The 6300AXX8 series is an 8 high brightness version of our timer display Box contents 1 Display 1 24VAC adapter w 20ft Wire 1 Screwdriver 1...

Отзывы: