![Microframe Corporation 6300 8 Series Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/microframe-corporation/6300-8-series/6300-8-series_installation-and-specifications-manual_1786407014.webp)
Microframe Corporation
14
604 South 12
th
Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com
Series 6300XXX8
2 Behavior
2.1 Operation
2.1.0 Wall Clock
2.1.1 Count Up
2.1.2 Countdown
2.1.3 Slave Display
2.1.4 Unit Counter
2.1.5 Takt Time
2.2 Clock Format
2.2.0 12 hr
2.2.1 24 hr
2.3 Display Format
2.3.0 As time
2.3.1 As interval (see 2.4)
2.3.2 As date
2.3.3 As count (for 2.1.4 and 2.1.5)
2.4 Interval Unit
2.4.0 Hundredths of a second
2.4.1 Seconds
2.4.2 Minutes
2.4.3 Hours
2.4.4 Days
Options Table Summary
Options in
bold
are the Default settings from Microframe.
** = Option 6.3 Does not apply to this hardware. Please leave at 6.3.0!
1 Setup
1.1 Set Current Time
1.2 Set Current Date
1.3 Set Reload Time/Interval
1.4 Set Chime 1 Time/Interval
1.5 Set Chime 2 Time/Interval
1.6 Quicksets
1.6.0 Wall Clock
1.6.1 Days Accident Free
1.6.2 Days Count Down
1.6.3 Countdown to New Year's Day
1.6.4 Count Up Time from zero
1.6.5 Countdown Time from 1 hour
1.6.6 Countdown Interval - 90 minutes
1.6.7 Unit Counter
1.6.8 Takt Time - 15-Second Interval
1.6.9 Reset Onboard Clock
1.7 Photocell Calibration
3 Chime
3.1 Internal Chime Duration
3.1.0 Off
3.1.1 Single Chime
3.1.2 Double Chime
3.2 External Chime Duration
3.2.0 Chime off
3.2.1 0.1 seconds
3.2.2 0.2 seconds
3.2.3 0.3 seconds
3.2.4 0.5 seconds
3.2.5 1.0 seconds
3.2.6 3.0 seconds
3.2.7 5.0 seconds
3.2.8 10.0 seconds
3.2.9 20.0 second
3.3 Chime Volume [Internal Chime]
3.3.0 Off
3.3.1 1 Soft
3.3.2 2
3.3.3 3
3.3.4 4
3.3.5 5
3.3.6 6
3.3.7 7 Loud
3.3.8 8
3.3.9 9 Loudest
4 Display
4.1 STU Range Lock
4.1.0 Hundredths of seconds
4.1.1 Seconds
4.1.2 Minutes
4.1.3 Hours
4.1.4 Days (00-99)
4.1.5 Days (0100-9999)
4.2 LTU Range Lock
4.2.0 Hundredths of seconds
4.2.1 Seconds
4.2.2 Minutes
4.2.3 Hours
4.2.4 Days (00-99)
4.2.5 Days (0100-9999)
4.3 Leading Zeroes
4.3.0 Show
4.3.1 Hide
4.4 Colon Flash Rate
4.4.0 Off
4.4.1 Alternate every second (1s)
4.4.2 Flash every second (0.5s)
4.4.3 Flash twice per second (0.25)
4.4.4 On (when running)
4.5 Size (factory set)
4.5.2 2 digit display
4.5.3 3 digit display
4.5.4 4 digit display
4.5.6 6 digit display
5 Events
5.1 On Rollover (Count Up)
5.1.0 Stop
5.1.1 Continue
5.2 On Zero
5.2.0 Stop
5.2.1 Reload and stop
5.2.2 Reload and continue
5.2.3 Count up
5.2.4 Flash zero
5.3 Chime on zero (count down)
5.3.0 OFF
5.3.1 Momentary
5.3.2 Continuous
6 Inputs
6.1 Input 1 Action
6.1.1 Stop
6.1.2 Start
6.1.3 Start/Stop
6.1.4 Reset
6.1.5 Stop + Reset
6.1.6 Reset + Start
6.1.7 Start/Stop/Reset
6.1.8 One-button mode
6.2 Input 2 Action
6.2.1 Stop
6.2.2 Start
6.2.3 Start/Stop
6.2.4 Reset
6.2.5 Stop + Reset
6.2.6 Reset + Start
6.2.7 Start/Stop/Reset
6.3 Pushbutton / Voltage **
6.3.0 Pushbutton, no external voltage
6.3.1 External 12V logic signal
6.4 N.O./N.C.
6.4.0 Normally open or no voltage
6.4.1 Normally closed or 12V
6.5 Button State
6.5.0 Momentary
6.5.1 Change of State (C.S.)
6.6 Button Debounce
6.6.0 None (not recommended)
6.6.1 Fast
6.6.2 Normal
6.7 IR Lockout
6.7.0 Ignore remote
6.7.1 Respond to remote
6.8 Keyfob Address
6.8.0 Address 0
6.8.1 to 6.8.9 Address 1 to 9