Operations Definitions continued…
Behavior
2.1 Operation
Determines the fundamental behavior of the display.
•
2.1.0 Wall Clock
Shows the current time or date
•
2.1.1 Count Up
Counts up by time or interval
•
2.1.2 Countdown
Counts down by time or interval
•
2.1.3 Slave Display
Shows information from a master display
•
2.1.4 Unit Counter
Counts parts or events
•
2.1.5 Takt Timer
Keeps track of Takt time
2.2 Clock Format
Allows the clock to show time in standard 12-hour format or in 24-hour military time.
2.3 Display Format
Determines how the unit displays information to the user. This may be changed freely without disrupting the running
time (see caution below about interval units.) Display formats do not apply to all modes. Slave displays will only show
the date if the master is also showing the date.
•
2.3.0 As time
Show in standard time format
DDDD.HH:MM:SS.hh (hundredths of a second)
Max: 9999.23:59:59.99
Applies to: 2.1.0, 2.1.1, 2.1.2, 2.1.3
•
2.3.1 As specified interval
Show by the interval specified in 2.4
Max: 65535 days, 999999 all other units
Applies to: 2.1.1, 2.1.2, 2.1.3
•
2.3.2 As date
Show the date
Applies to: 2.1.0, 2.1.3
•
2.3.3 As count
Show the current unit count
Applies to: 2.1.3, 2.1.4, 2.1.5
2.4 Interval Unit
Determines by what unit the time is displayed. Option 2.3.1 must be set for this option to take effect.
Caution
: Changing to a smaller interval unit, such that the resulting number is too large to display, will cause a
display overflow. If the display is stopped or counting down, you will see bars across the top of the screen. If the
display is counting up, the On Rollover event will be triggered. Triggering this event modifies your time! With this in
mind, you are free to change this setting even while the display is running. For safety, set this option to days before
changing the display format to interval.