A. XP-GT/GTR Single Door Access Control System
i. Powering Up
Before powering up the controller for the first time, check that all the connections to the
hardware are connected properly according to the wiring diagram.
For first time controller start-up, perform a ColdStart operation to reset all controller
settings to default. For all new installation, ColdStart operation only needed to be
performed once unless specifically instructed to do so.
XP-GT/GTR (1200, 3000, 3200, 1200L, 3000L, 3200L) Series
To perform ColdStart, please follow the steps below:
1. Turn ON the power supply. The screen below will be shown:
MicroEngine
XP-GT3200L
v3.00
Starting up...
2. While the controller is starting up, press the
#
button.
3. Press
√
to ColdStart the system, or
X
to cancel.
4. Press
√
again to confirm the ColdStart operation. Once the ColdStart process
finishes, the controller will automatically enter Idle Mode.
XP-GT/GTR (1500L, 3500L, 1500ABL, 3500ABL) Series
To perform ColdStart, please follow the steps below:
1. Ensure that the power supply is turned off.
2. Press and hold the ColdStart button at the back of the controller.
3.
Turn ON the power supply. Release the ColdStart button after 2 seconds.
4.
Controller will sound a long beep during the ColdStart operation and will
automatically enter Idle Mode once ColdStart process finishes.
.