Maintenance
Maintenance – Software Update
Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019
93
17.3.2
Select active image
Figure 17-5: Selecting active software image
This page allows you to revert to the previous (alternate) image before the latest software update.
Pressing on the
Activate Alternate Image
will issue a warning message with an option to cancel the
reverting process. If you opt to continue the reverting process, the image bellow will be displayed during
the software reverting process.
Figure 17-6: Switching active image
NOTES:
1 - If the active firmware image is the alternate image, only the "Active Image" table is shown. In
this case, the Activate Alternate Image button is also disabled.
2 - If the alternate image is active (due to a corruption of the primary image or by manual
intervention), uploading a new firmware image to the device will automatically use the primary
image slot and activate this.
3 - The firmware version and date information may be empty for older firmware releases. This
does not constitute an error.