Page 23
Installation and Assembly
optoCONTROL CLS1000
Switching output Q1 properties
Sensor
pin
PC1000-x
cable color
Comments
V
+
max. 12 ... 30 VDC, I
max
= 100 mA
Signal level depends on supply voltage
Switching behavior programmable: NPN, PNP, PP
4
Black
Switching output Q1
3
Blue
Ground
4.5.4.4 Trigger Input CLS1000-AI-xx-T
Only applies for controller CLS1000-AI-xx-T with trigger function.
The trigger input enables recording of measurement values/output of measurement values with averaging, as well as
various trigger types
V
+
Trigger
1
5
4
Q
PP / PNP / NPN
I Analog
0/4 mA
20 mA
2
GND
3
Blue
Brown
White
Black
Gray
Fig. 18 Circuit for CLS1000-AI-xx-T
Trigger input properties
Sensor
pin
PC1000-x
cable color
Comments
3
Blue
Ground
max. 30 VDC; input current
I
max
= < 1 mA
5
Gray
Trigger (IN)
When wiring the trigger input with an NPN output, an external resistance
≥ 4.7 kΩ ≤ 10 kΩ is necessary.