Page 37
Operation
optoCONTROL CLS1000
5.4.4
Q1 / Config Q1
The
Q1
menu for the switching output Q1
is available in all models of the optoCONTROL CLS1000.
Switching polarity
Q1
OPM
Output type
Q1
TYPE
Hysteresis
Q1
HYS
Switching threshold
Q1
TRH
Timer
Q1
TIME
Config Q1
MENU
Q1
OPM
2
1
0
0
Values:
- L-SW: Light switching
- D-SW: Dark switching
Value
TYPE
2
2
0
0
Values:
Value
- PP: PushPull
- PNP: PNP-Type
- NPN: NPN-Type
HYS
2
3
0
0
Values:
Value
2 ... 25 [%]
TRH
2
4
0
0
Values:
Value
100 ... 4000 [Bit]
2
0
0
0
Timer-Art
TIME
TYPE
Timer-Wert
TIME
VAL
2
5
0
0
TYPE
2
5
1
0
Values:
Value
VAL
2
5
2
0
Values:
Value
1... 9999 [ms]
- OFF: No timer
- OND: On-delayed
- OFFD: Off-delayed
- IMP: Pulse output
Fig. 35 Q1 / Config Q1 menu
5.4.4.1 OPM / Switching Polarity
In
OPM
mode, the setting can be
Light switching
or
Dark switching
.
5.4.4.2 TIME / Timer
In
TIME
mode, the
TYPE
(timer type) can be set:
- OFF: No timer
- OND: On-delayed
- OFFD: Off-delayed
- IMP:
Pulse output
In
VAL
mode (timer value), the value
for the respectively set time switching can be set, on-delay, off-delay or pulse output
between 1 .... 9999 ms.
5.4.4.3 Q2 / Config Q2
The
Q2
menu is available in the optoCONTROL CLS1000-2Q model
.
The menu structure is identical to the menu structure of Q1 / Config Q1