Page 20
Installation and Assembly
optoCONTROL CLS1000
4.5.3
Model CLS1000-AU
4.5.3.1 Pin Assignment
Pin
Signal/assign-
ment
Description
Comments, circuitry
PC1000-x
cable color
1
2
3
4
1
2
3
4
5
1
V
+
Supply voltage
12 ... 30 VDC
I
max
< 50 mA
Brown
2
OUT2
Analog output
0 ... 10 VDC
R
a
> 10 kOhm
White
Fig. 9 4-pin ca-
ble socket,
view of solder
side
Fig. 10 5-pin cable
socket,
view of solder
side
1
3
GND
Ground
Ground for supply, switch-
ing output Q and analog
output and trigger (IN)
1
Blue
4
OUT1
Switching out-
put Q1
V
+
max. 12 ... 30 VDC,
I
max
= 100 mA, Signal level
depends on supply volt-
age, switching behavior
programmable: NPN, PNP,
PP
Black
5
1
TRG
1
Trigger (IN)
1
max. 30 VDC; input current
I
max
= < 1 mA
Gray
1
1) Only for controller CLS1000-AU-xx-T with trigger function
Alternatively, for the model without trigger function, an angled signal/power supply cable PC1000/90-x with a connector
angled at 90° (or open ends) is available
(optional accessories).
4.5.3.2 Analog Output
The sensor supplies an output voltage of 0 ... 10 VDC.
Analog output properties
Sensor
pin
PC1000-x
cable color
Comments
Voltage output
0 ... 10 V
2
White
Analog output
R
a
> 10 KOhm
3
Blue
Ground
Fig. 11 Analog output switching
4.5.3.3 Switching Output
The switching variants of the switching output (PP/PNP/NPN) as well as the switching thresholds can be changed and
adjusted using the Operating menu.
The switching behavior (NPN, PNP, push-pull (PP)) of the switching output depends on the programming.
GND
1
3
4
Q
PP / PNP / NPN
U Analog
0 V
10 V
2
V
+
Brown
White
Black
Blue
Fig. 12 Circuit for switching output CLS1000-AU