Page 24
Installation and Assembly
optoCONTROL CLS1000
4.5.5
Model CLS1000-QN
4.5.5.1 Pin Assignment
Pin Signal/assign-
ment
Description
Comments, circuitry
PC1000-x
cable color
1
2
3
4
1
2
3
4
5
1
V
+
Supply voltage
12 ... 30 VDC
I
max
< 50 mA
Brown
2
OUT2
Switching output
QN
V
+
max 12...30 V DC,
I
max
= 100 mA, signal
level depends on sup-
ply voltage.
Switching behavior
programmable
2
: NPN,
PNP, PP
White
Fig. 19 4-pin
cable socket,
view of solder
side
Fig. 20 5-pin ca-
ble socket,
view of solder
side
1
3
GND
Ground
Ground for supply,
switching output QN
and switching output Q
and trigger (IN)
1
Blue
4
OUT1
Switching output Q
V
+
max 12...30 V DC,
I
max
= 100 mA, signal
level depends on sup-
ply voltage.
Switching behavior
programmable
2
: NPN,
PNP, PP
Black
5
1
TRG
1
Trigger (IN)
1
max. 30 VDC; input
current
I
max
= < 1 mA
Gray
1
1) Only for controller CLS1000-QN-xx-T with trigger function
2) The switching behavior is programmable and identical for switching output QN and switching output Q.
Alternatively, for the model without trigger function, an angled signal/power supply cable PC1000/90-5 with a connector
angled at 90° (or open ends) is available with shielding
4.5.5.2 Switching Outputs
The switching variants of the switching outputs (PP/PNP/NPN) as well as the switching threshold can be changed and
adjusted using the operating menu.
NO (Q) + NC (QN) = antivalent
The controller supplies both signals. Both outputs are switched upon detection of an object.
This is often required for detection with wire breakage protection. The PLC always expects an active or passive signal;
when this state is not the case, wire breakage or another error is the cause.
1
3
2
4
Q
Q
GND
PP / PNP / NPN
PP / PNP / NPN
V
+
Brown
White
Black
Blue
Fig. 21 Circuit for CLS1000-QN