9
Charge current
- Charge current in A.
Discharge current
- Discharge current in A.
Cycle delay time
- Pause between the cycle charge/ discharge phases
(1-20 min).
Cycle order
- D->C (Discharge -> Charge), C->D (Charge -> Discharge).
Cycle time
- Number of cycles (1-5).
3.6.2 Saving the Settings
If you often use the same battery you can save the parameter settings
into the memory of your charger (up to 8 programs). The procedure is the
same as described in 3.5.2.
3.6.3 Launching the Process
Once you are satisfied with the parameters you have set (refer to 3.6.1)
touch the “START” icon to launch the desired process.
Alternatively, enter the Memory menu to select one of the previously
stored charge/discharge programs (refer to 3.6.2) and touch the “START”
icon.
3.6.4 Working
Interface
Once the charge/
discharge process
has been started
there is only one
screens of the
working interface
available: total voltage vs. time graph. The displayed parameter values
are the same as described in 3.5.4.
3.6.5 Stopping the Process
You can stop the process by touching the “STOP” icon anytime.
3.7 Pb (Lead-Acid) Program
Batt.
Type Program
Description
Pb
TRICKLE
This mode is for trickle charging Pb batteries.
CHARGE
This mode is for charging Pb batteries.
DISCHARGE This mode is for discharging Pb batteries.
3.7.1 Setting the Parameters
Enter the PB menu.
Select the Charge
mode “CHARGE”
and set all the
parameters as
required.
Battery cell
- Number of cells in your battery pack.
End voltage
- Charge/Discharge terminal voltage in mV per cell.
Charge current
- Charge current in A.
Discharge current
- Discharge current in A.
3.7.2 Saving the Settings
If you often use the same battery you can save the parameter settings
into the memory of your charger (up to 8 programs). The procedure is the
same as described in 3.5.2.
3.7.3 Launching the Process
Once you are satisfied with the parameters you have set (refer to 3.7.1)