6
(CH1/CH2 Max Power)
- In this menu you can allocate the output
charge power (total max. 400 W) available for channels CH1 and CH2.
Range 300 W/100 W to 100 W/300 W. Default: 200 W/200 W.
(Balance Speed)
- In this menu you can the balance control rate for
lithium batteries. Range: fast, normal, slow. Default: normal.
Fast: Fastest balance speed, less accurate / Slow: Lowest balance speed,
more accurate / Normal: A compromise between the speed and accura-
teness of the balancing.
3.1.2 CH1 SETTINGS/CH2 SETTINGS
(Int. Temp cut-off)
- In this menu you can set the cut-off internal
temperature in order to protect your charger. The charger will stop the
process when its internal temperature exceeds the pre-set temperature
limit. Range: 30-85°C. De-
fault: 80°C.
(Capacity cut-off)
- In
this menu you can set the
cut-off capacity in order
to protect your battery.
The charger will stop the
process when the capa-
city exceeds the pre-set
limit. Range: Off, 0.1-65.0 Ah. Default: 10.0 Ah
(Ext. Temp cut-off)
- In this menu you can set the cut-off external
temperature in order to protect your battery. The charger will stop the
process when the temperature of your battery (requires the optional
temperature sensor attached) exceeds the pre-set limit. Range: Off, 30-
85°C. Default: 60°C.
(Safety Time cut-off)
- In this menu you can set the cut-off time in
order to protect your battery. The charger will stop the process when the
time exceeds the pre-set limit. Range: Off, 1-600 min. Default: 240 min.
3.1.3 Saving/Resetting the Settings
Once you are satisfied with your settings, touch “SAVE & BACK” icon to
save the settings and return to the Main Menu.
You can reset all the Public/CH1/CH2 settings to default values by tou-
ching the “RESET” icon anytime.
3.1.4 Returning to the Main Menu
Touch the “BACK” icon to return to the Main Menu.
3.2 Memory Menu
Enter the Memory menu.
3.2.1 Launching a Stored Charge/Discharge Program
Select the one of the memory slots and touch the “START” icon to launch
the desired charge/discharge program.
3.2.2 Modifying a Stored Charge/Discharge Program
Select the one of the memory slots and touch the “MODIFY” icon to edit
the existing settings.
Note:
You cannot change the battery type in this menu as well as some
other parameters; generally, you can edit just the charge/discharge current
and end voltage/delta V values. If you decide to replace the stored memory
with completely different battery type settings you will have to enter the
respective battery menu and save a new set of settings (refer to 3.5.2 Saving
the Settings) into the desired memory slot.
3.2.3 Returning to the Main Menu
Touch the “BACK” icon to return to the Main Menu.