20302381
5
Designer Series Direct Vent Gas Fireplace
FP2815
designer controls
PRoDuCT FeaTuReS
PRoDuCT SPeCIFICaTIoNS
•
This appliance has been certified for use with either natural or propane gas.
See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting room installations.
•
The appliance must be installed in accordance with local codes if any. If none
exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA
B149 in Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a venting system.
•
The appliance is not approved for closet or recessed installations.
GaS PReSSuReS
hIGh eLeVaTIoNS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
GaS SPeCIFICaTIoNS & oRIFICe SIZe
Figure 1 -
Designer Controls
FP2815
Control Box
Gas Valve
Command
Center
Max.
Min.
Input
Input orifice
Model
Fuel Controls BTu/h BTu/h
Size
PFLDVNS
Nat.
SCS
37,000 25,000
#31
PFLDVPS
LP
SCS
35,000 27,000 1.8 mm
STLDVNS
Nat.
SCS
37,000 25,000
#31
STLDVPS
LP
SCS
35,000 27,000 1.8 mm
CLLDVNS
Nat.
SCS
37,000 25,000
#31
CLLDVPS
LP
SCS
35,000 27,000 1.8 mm
CRLDVNS
Nat.
SCS
37,000 25,000
#31
CRLDVPS
LP
SCS
35,000 27,000 1.8 mm