CLeaRaNCeS
CLeaRaNCeS To CoMBuSTIBLeS
Follow these instructions carefully to ensure safe installation. Failure to
follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible
material other than wood flooring. If installed on carpet or vinyl flooring, the
appliance shall be installed on a metal, wood or noncombustible material
panel extending full width and depth of the appliance.
45°
1”
4”
5”
6”
”
3”
FP2818
mantel leg clearance
MaNTeL CLeaRaNCeS
NoTe:
The combustible area above the facing must
not protrude more than 1/2" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
Never obstruct or modify the air inlet or
outlet grilles (louvers). This may create
a fire hazard.
Figure 10 -
Mantel Clearance
72”
(1829 mm)
Min.
Ceiling
6”
(152 mm)
Min.
FP2832
ceiling wall clearance
Figure 9 -
Ceiling and Side Wall Clearances
Combustible Mantel
FP2544
Stud
Combustible
Material Area
FP2818
Top View
w
a
RNING
FP2817
mantel clearances
16”
12”
10”
12”
6”
2
56O
”
Side View
Noncombustible
Material to Top of
Standoffs
FP2817
Top of Fireplace
Opening
w
a
RNING
12"
(305 mm)
Max. Depth
16"
(406 mm)
Min.
Spacer
Side of Fireplace
Opening