14
20302381
Designer Series Direct Vent Gas Fireplace
VeNTING INSTaLLaTIoN
INSTaLLaTIoN PReCauTIoNS
Consult local building codes before beginning the installation. The installer must make sure to
select the proper vent system for installation. Before installing vent kit, the installer must read
this fireplace manual and vent kit instructions.
Only a qualified installer/service person should install the venting system. The installer must
follow these safety rules:
•
Wear gloves and safety glasses for protection.
•
Use extreme caution when using ladders or when on rooftops.
•
Be aware of electrical wiring locations in walls and ceilings.
The following actions will void the warranty on your venting system:
•
Installation of any damaged venting component.
•
Unauthorized modification of the venting system.
•
Installation of any component part not manufactured or approved by MHSC
•
Installation other than permitted by these instructions.
Read all instructions completely and thoroughly before attempting
installation. Failure to do so could result in serious injury, property damage
or loss of life. operation of improperly installed and maintained venting
system could result in serious injury, property damage or loss of life.
w
a
RNING
Failure to follow these instructions will
void the warranty.
N
o
TIC
e
oPTIoNaL ToP VeNT aPPLICaTIoN
The appliance is shipped as a rear vent unit. If the installa-
tion layout requires the unit to be a top vent configuration,
the appliance can be converted by following the steps
below.
When removing and refitting the plates and adapter, be
sure the associated gaskets are undamaged and refitted
as required.
1. Remove the eight (8) screws securing the flue pipe
adapter to the fireplace body.
Figure 12
2. Set the flue pipe adapter aside, complete with the
gasket. Do not damage the gaskets as the adapter and
gasket must be refitted.
3. Remove the eight (8) screws securing the flue pipe cover
to the top of the intake box and remove the cover and
gasket.
Figure 12
FP2895
remove top cover
Remove for Top Vent
applications
FP2895
Figure 11