ADI LT boiler - Technical Manual
Page
L338
11/2011
58
Alba_Nr
Diagn_Nr
DIAGNOSIS
TEXT
REACTION
Complementary
166
81
AIR PRESSURE SWITCH
APS (air pressure switch) does not open if it turns off (¿contacts pegados?)
Lock-out - reset
LP does not open with the boiler stopped (¿contactos
pegados?)
181
169
MAINTENANCE FUNCTION
Function Controller Stop is activated
Message (only if the controller stops)
No more difference with respect to Albatros code
183
104
LMU CONTROL UNIT IN
SETTING/PROGRAMMING MODE
Change to programming mode (by means of PC)
Shut-off for safety with start prevention
Change to programming mode (by means of PC)
183
105
The unit is in the programming mode (by means of PC)
Lock-out - reset (mode Prog.)
Operating in the programming mode (by means of PC)
183
279
Via OT bus, parameters setting is requested
Shut-off for safety with start prevention
No more difference with respect to Albatros code
183
497
Via LPB, parameters setting is requested
Shut-off for safety with start prevention
Demand for programming via LPB
184
602
MODEM ACTIVATED
Funtion Modem is activated
Message
Alba_Nr
Diagn_Nr
DIAGNOSIS
TEXT
REACTION
Complementary
166
81
AIR PRESSURE SWITCH
APS (air pressure switch) does not open if it turns off (¿contactos
pegados?)
Lock-out - reset
LP does not open when the boiler stops (¿contactos
pegados?)
181
169
FUNCTION MAINTENANCE
The function Controller Stop is activated
Message (only if the controller stops)
No more difference with respect to Albatros code
183
104
LMU CONTROL UNIT IN SETTING
/PROGRAMMING MODE
Change to programming mode (by means of PC)
Off for safety with start prevention
Change to programming mode (by means of PC)
183
105
The unit is in programming mode (by means of PC)
Lock-out - reset (Programming mode)
Operating in programming mode (by means of PC)
183
279
Parameters setting required, via OT bus
Off for safety with start prevention
No more difference with respect to Albatros code
183
497
Parameters setting required, via LPB
Off for safety with start prevention
Demand of programming via LPB
184
602
MODEM ACTIVATED
The function Modem is activated
Message
Содержание ADI LT
Страница 1: ...L338 11 2011 INSTALLATION OPERATION AND MAINTENANCE MANUAL ADI LT LOW TEMPERATURE BOILER ...
Страница 29: ...ADI LT boiler Technical Manual Page L338 11 2011 29 12 1 ELECTRIC DRAWING ADI LT 105 ADI LT 200 ...
Страница 30: ...ADI LT boiler Technical Manual Page L338 11 2011 30 12 2 ELECTRIC DRAWING ADI LT 250 ADI LT 325 ...
Страница 31: ...ADI LT boiler Technical Manual Page L338 11 2011 31 12 3 ELECTRIC DRAWING ADI LT 400 ADI LT 750 ...
Страница 59: ...L338 11 2011 ...