26 Instructions GD0

6 Technical characteristics

GD0 is produced by NICE S.p.a. (TV) I, MHOUSE S.r.l. is an affiliate of the NICE S.p.a. group.

Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In any case,
the manufacturer guarantees their functionality and fitness for the intended purposes.

Note: all the technical characteristics refer to a temperature of 20°C.

GD0K gearmotor for sectional and overhead  door

Type

Electromechanical gearmotor for automated  sectional and overhead doors incorporating a control unit com-
plete with radio receiver for “TX4” transmitters.

Adopted technology

24Vdc motor, helical teeth reduction gear; drive guide with timing belt and mechanical release  A transformer
inside the motor but separated from the control unit reduces mains voltage to the nominal voltage of 24Vdc
used by the automation system.

Peak thrust
[corresponds to the force necessary to
move a leaf]

9.9Nm

[550N]

Nominal torque
[corresponds to the force necessary to
keep a leaf moving]

4.95Nm

[275N]

Speed under no load
[corresponds to if “Fast” speed is
programmed]

103rpm

[0.14m/s]

The control unit allows 2 speeds to be programmed equal to approx. 100% - 60%.

Nominal torque speed
[corresponds to if “Fast” speed is
programmed]

52rpm

[0.07m/s]

Maximum frequency of cycles

30 complete cycles per day (the control unit allows up to a maximum of 10 cycles per hour)

Maximum continuous cycle time

3 minutes (the control unit limits the continual function to 3 minutes at nominal torque)

Working Limits

Its structural characteristics make it suitable for use on  sectional and overhead door  with counterweights
within the following parameters: 
- Sectional doors: 240cm max. high - 300cm (7.2 m

2

) max. wide -  maximum torque 55kg

- Overhead doors: 240cm max. high - 270cm (6.48m

2

) max. wide -  maximum torque 55kg

Power supply GD0
Power supply GD0/V1

230Vac (±10%) 50/60Hz
120Vac (±10%) 50/60Hz

Max. absorbed power

200W

Insulation class

1 (a safety grounding system is required)

Emergency power supply

---

Flashing light output

For visual signalling devices with 12V lamp, maximum 21W

Courtesy light 

12V lamp maximum 21 WBA15 socket (automotive type lamp), stays on 60s after the manoeuvre 

“PHOTO” input       

For safety devices such as the PH0 photocell

“OPEN” input  

For normally open contacts (the closing of the contact causes the “OPEN” command)

STOP input

For normally open contacts and/or for 8.2K

constant resistance, or normally closed contacts with recogni-

tion of the “normal” status (any variation from the memorized status causes the “STOP” command)

Radio aerial input 

52

for RG58 or similar type of cable

Maximum cable length

Mains power supply: 30m; inputs/outputs: 20m with aerial cable preferably shorter than 5m (observe the
directions regarding the minimum gauge and type of cable)

Remote control possibility

with TX4 transmitters, the control unit can receive one or more of the following commands: “OPEN”, “Open
partially”, “Open only” and “Close only”

TX4 transmitters memorized

Up to 150 if memorized in mode 1

Range of TX4 transmitters

From 10 to 50 m without aerial, from 50 to 100 m with aerial incorporated in the FL1 flashing light.
The range can vary if there are obstacles or electromagnetic disturbances, and is affected by the position of
the receiving aerial incorporated in the flashing light.

Programmable functions

“Cycle” or “Complete cycle” operation (automatic closing)
“Slow” or “fast” motor speed.
The pause time in the “complete cycle” mode can be set at 15, 30, 60 seconds.
The type of pedestrian opening can be selected from 4 modes. The sensitivity of the obstacle detection sys-
tem can be selected from 3 levels. The operation of the “Open” command can be selected from 3 modes

Self-programmed functions

Automatic detection of the type of “STOP” device (NO or NC contact or 8.2K

resistance) Automatic detec-

tion of door length and calculation of deceleration points

Operating ambient temperature

-20 ÷ 50°C

Not suitable for use in acid, saline or
potentially explosive atmosphere

NO

Mounting 

Horizontal

Protection class 

IP40

Dimensions / weight

390 x 210 x h 130mm / 3kg

Содержание GD0

Страница 1: ...Installation instructions and warnings English IST GD0 GB 4865 Rev 00 del 15 03 2005 MhouseKit GD0 For the automation of a sectional or overhead door...

Страница 2: ......

Страница 3: ...ent that liquid substances have penetrated inside the automation devices immediately disconnect the power supply and contact the MHOUSE customer service department The use of GD0 in these conditions c...

Страница 4: ...stops E GD0K gearmotor 2 2 Description of the automation A B Figure 1 2 Product description 2 1 Applications GD0 is a set of components designed for the automation of sectional or overhead doors in re...

Страница 5: ...of devices GD0K is an electromechanical gearmotor consisting of a 24V direct cur rent motor It features a mechanical release mechanism with cord that allows you to move the door manually in the event...

Страница 6: ...nits The transmission of the command is confirmed by the LED A an eyelet B allows them to be hung on a keyring Figure 7 B A The pair of PH0 wall mounted photocells once they are connected to the contr...

Страница 7: ...e guide and the brackets to the ceiling The head of the guide will have to bear all the strain of opening and closing the door the ceiling mounted brackets will have to bear all the weight of GD0 In b...

Страница 8: ...m 7 2m2 max width max imum torque 55kg Overhead garage doors 240cm max height 270cm 6 48m2 max width maximum torque 55kg The shape of the door and the climatic conditions e g presence of strong wind m...

Страница 9: ...ces refer to figure 13 you can start preparing the conduits for the electrical cables connecting the devices to the control unit The shock resistant conduits are designed to protect the electrical cab...

Страница 10: ...and related washer as in fig 18 7 Hook the upper carriage E to the lower carriage C and place the entire carriage assembly inside the guide as in fig 19 8 Assemble the Guide B head as in fig 20 This...

Страница 11: ...d lift the guide from the front and secure it with two screws anchors or riv ets depending on the type of surface 3 Secure the mounting brackets L using the screws M and nuts N and choosing the hole t...

Страница 12: ...all the strain resulting from opening and clos ing the door 9 Loosen the screws in the two mechanical stops then place the front mechanical stop O before the carriage Figure 33 Push the carriage hard...

Страница 13: ...he edge of the door With sectional doors the photocells can be mounted outside whereas with overhead doors they can only be mounted inside outside they would obstruct the movement of the door Point tr...

Страница 14: ...the hole for the passage of the cables in the bottom or side depending on the installation position using a screwdriver 5 Mark the drilling points using the bottom as reference and make sure that the...

Страница 15: ...ove the small piece of wire between ter minals 3 and 7 and make the connections as in Fig 56 if using the flashing light aerial remove the piece of wire which is con nected to terminal 2 and connect t...

Страница 16: ...ly an external aerial can be used or the small piece of wire that is already connected to the terminal can be left which acts as an aerial 3 4 OPEN input for manoeuvre control devices Normally Open ty...

Страница 17: ...t manoeuvres are not interrupted by any commands If the manoeuvres are not completed repeat the recognition procedure starting from step 1 The position recognition stage can be repeated at any time in...

Страница 18: ...en carefully observed 2 Using the selector switch if provided or the radio transmitter test the opening and closing of the door and make sure that the door moves in the intended direction The test sho...

Страница 19: ...directions provided in the corre sponding maintenance schedule 4 Maintenance 3 7 2 Commissioning The commissioning operations can be performed only after all the tests have been successfully carried...

Страница 20: ...force OPEN function 1 Open Stop Close Stop Press button T2 once 2 Open Stop Close Open Press button T2 twice 3 Open Open Open Open opening only Press button T2 three times The following chapters descr...

Страница 21: ...as described in the Photocell instructions in the event there are two pairs of photocells that could interfere with one another 5 3 2 STOP Input STOP is the input that causes the immediate interruptio...

Страница 22: ...n partially Open only and Close only can be associated to each button In Mode 2 each button requires a separate memorization stage 1 Press button P1 figure 71 on the control unit as many times as the...

Страница 23: ...ion stage or in case of failure Table 10 Symptoms probable cause and possible solution The radio transmitter does not emit any sig nal the LED A does not light up Check to see if the batteries are exh...

Страница 24: ...s pause 2 flashes Triggering of a photocell At the starting of the manoeuvre one or more photocells do not enable it check to see if there are any obstacles If there is an obstacle impeding the movem...

Страница 25: ...tion in progress On Memorization in Mode 1 This is normal during memorization in mode 1 which lasts maximum 10s Series of quick flashes from 1 to 4 Memorization in Mode 2 This is normal during memoriz...

Страница 26: ...r 200W Insulation class 1 a safety grounding system is required Emergency power supply Flashing light output For visual signalling devices with 12V lamp maximum 21W Courtesy light 12V lamp maximum 21...

Страница 27: ...ontrol units Lamp 12V 21W BA15 socket automotive type lamp Power supply contacts The device can only be connected to the FLASH output terminals 9 10 and ARIEL input 1 2 of the MHOUSE automation contro...

Страница 28: ...Operating ambient temperature 20 50 C Use in acid saline or potentially explosive atmosphere No Protection class IP40 suitable for use indoors or in protected environments Dimensions weight 72 x 31 h...

Страница 29: ...L of 9th March 1999 concerning radio equipment and telecommunications terminal equipment and mutual recognition of their conformity According to the following standards ETSI EN 300 220 3 ETSI EN 301 4...

Страница 30: ......

Страница 31: ...nufacture Location address Satisfies the essential requirements of the following Directives 98 37 EC Machine Directive 89 336 ECC Electromagnetic Compatibility Directive 73 23 ECC Low Voltage Directiv...

Страница 32: ......

Страница 33: ...control or key operated selector switch If the safety devices enable the operation the door will open normally otherwise actuate the control again within 3 seconds and keep it actuated 2 After approx...

Страница 34: ...balanced door could cause injury If the range of the remote control is significantly diminished and the light emitted by the LED is feeble the remote control battery is probably exhausted The remote c...

Страница 35: ......

Страница 36: ...Mhouse Via Pezza Alta 13 Z I Rustign 31046 Oderzo TV Italia Tel 39 0422 20 21 09 Fax 39 0422 85 25 82 info mhouse biz www mhouse biz...

Отзывы: