XTreme-EMS Operating Manual
Page 52
The Xtreme-EMS must be setup as follows:
RPM 1:
PULSES/REV: 1.0
Fuel Flow:
K-FACTOR 1: 3500
MODE: FLOW SENDER
Manifold Air Pressure:
No change needed
Oil Pressure
:
TYPE: Resistive
SENDER: User
CALIBRATE SENDER:
POINTS: 2
DISPLAY 1: 0.0 bar
ADC 1: 0000
DISPLAY 2: 10.0 bar
ADC 2: 4095
Oil Temperature:
SENDER: LM335
LM335: 0
Coolant Temperature:
This is remapped to ANALOG AUX1
FUNCTION: TEMPERATURE
SENDER: LM335
LM335: 0
EGT 1,2,3,4
EGT CHANNELS: 4
Throttle Position:
0-100% can be viewed in the ECU Setup ROTAX 912iS section
Engine Ambient Pressure:
This can be viewed in the ECU Setup ROTAX 912iS section
Fuel Level senders:
This is setup as normal in the fuel setup menu
Fuel pressure sender:
This is setup as normal in the fuel setup menu
DC current input:
This is setup as normal in the current setup menu.
Please see the RDAC-CAN documentation for installation and usage.