4.3.1 RPM 1 Setup
RPM DISPLAY:
Select if you want the RPM to be displayed in
“RPM” or
“PERCENT”
.If you do not want any RPM information then set this
parameter to
"OFF"
. If the rotor RPM is set to "RPM" or "PERECENT" then the engine RPM display will automatically be
enabled.
RPM 100% DISPLAY:
Select the maximum value that you want the RPM to correlate to 100%.
RPM DISPLAY MAX:
Select the maximum RPM that you want the RPM dial to show. This can give you increased display resolution.
RPM DISPLAY MIN:
Select the minimum RPM that you want the RPM dial to show. This can give you increased display resolution.
HIGH ALARM:
This enables or disables the RPM high alarm.
HIGH ALARM:
Enter the RPM threshold for when the high alarm must be activated. Any RPM value above this value will activate the
alarm.
HIGH CAUTION:
Enter the RPM value for the high caution. This is the lower value of the upper yellow band.
LOW CAUTION:
Enter the RPM value for the low caution. This is the upper value of the lower yellow band.
LOW ALARM:
This enables or disables the RPM low alarm.
LOW ALARM:
Enter the RPM threshold for when the low alarm must be activated. Any RPM value below this value will activate the
alarm.