XTreme-EMS Operating Manual
Page 13
3.1.5 EGT / CHT display section
The XTreme supports up to 12 thermocouples for EGT / CHT. The EGT / CHT section will automatically try and
maximize the display area according to the number of EGT / CHT selected. The EGT / CHT parameters can be
configured in the
“EGT SETUP”
and
“CHT SETUP”
menu.
The EGT / CHT number will highlight to the indicated the temperature value if
“HIGHEST”
is selected. The EGT highlight
color is magenta, and the CHT color is cyan.
EGT / CHT Trend graph
The EGT / CHT trend displays can be accessed by pressing the 2
nd
left most button when the engine display screen is
shown. The trend graph displays the last 250 seconds of EGT/CHT temperature readings.
High Caution
High Alarm
Maximum temperature
reached indicator
Temperature unit
Indicates highest value if
“HIGHEST”
is selected or
the highlighted bar value
if
“SCANNING”
is selected
EGT group indicator
CHT group indicator