XTreme-EMS Operating Manual
Page 26
4.3.2 RPM 2 Setup
RPM DISPLAY:
Select if you want the RPM 2 to be displayed in
“RPM” or
“PERCENT”
.If you do not want any RPM 2 information then set
this parameter to off. If the RPM 2 is set to "RPM" or "PERECENT" then the engine RPM display will automatically be
enabled.
RPM 100% DISPLAY:
Select the maximum value that you want the RPM to correlate to 100%.
HIGH ALARM:
This enables or disables the RPM high alarm.
HIGH ALARM:
Enter the RPM threshold for when the high alarm must be activated. Any Rotor RPM value above this value will activate
the alarm.
HIGH CAUTION:
Enter the RPM value for the high caution. This is the lower value of the upper yellow band.
LOW CAUTION:
Enter the RPM value for the low caution. This is the upper value of the lower yellow band.
LOW ALARM:
This enables or disables the low alarm.
LOW ALARM:
Enter the RPM threshold for when the low alarm must be activated. Any RPM value below this value will activate the
alarm.
PULSES/REV:
Enter the number of pulses per RPM.
RESOLUTION:
Select the step size between successive RPM values eg. if the RPM value is 403 RPM and the
“RESOLUTION”
is 5
then the actual value shown is 405 RPM.
Содержание XTreme - EMS
Страница 23: ...XTreme EMS Operating Manual Page 23 4 3 EMS Setup...
Страница 70: ...XTreme EMS Operating Manual Page 70 12 Dimensions 12 1 Front view...
Страница 71: ...XTreme EMS Operating Manual Page 71 12 2 Side view Version 1 12 3 Top view Version 1...
Страница 72: ...XTreme EMS Operating Manual Page 72 12 4 Side view Version 2 12 5 Top view Version 2...