![Meyer E-60 QUIK-LIFT Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/meyer/e-60-quik-lift/e-60-quik-lift_service-manual_1781660052.webp)
FIGURE 3-84
Refill unit with Meyer M-1 Fluid 1” to 1-1/2” from Top
Cap with Ram all the way down.
FIGURE 3-85
To adjust operating pressure of the hydraulic unit, turn
the adjusting screw clockwise to raise the pressure
and counter clockwise to lower the pressure.
E-60 (1-1/4” Ram) Set pressure to 2500 ± 50 P.S.I.
E-60 & E-60H
Set pressure to 2000 ± 50 P.S.I.
REASSEMBLY - ALL MODELS
IMPORTANT: The valve cartridges can be damaged
beyond repair by bending or denting the tube, the
portion of the cartridge surrounded by the coil.
Therefore, do not grip the cartridge tube with pliers
or clamp it in a vise.
“A” CARTRIDGE
NOTE: Use only a 7/8” or a 1-1/8” hex deep socket
to remove and reinstall the “A” Cartridge.
The “A” Cartridge cannot be disassembled. When
operating normally, the poppet can be pushed in
approximately .030”.
Jamming of the poppet due to metal chips or other
contamination can usually be eliminated by immersing
the entire cartridge in clean kerosene and pushing the
poppet in and out with a probe until it moves freely.
Dry with compressed air and reinstall.
In the event jamming cannot be eliminated, replace
the cartridge.
VALVE CARTRIDGES “B” and “C”
Use only 1-1/4” hex deep socket to remove
Cartridges.
NOTE: Cartridges without a hex nut must use special
tool No. 21891 to remove and reinstall the “B” and “C”
Cartridges. See Figure 3-89 (page 53).
When jamming of the spool occurs, attempt to
eliminate it using the method described under “A”
Cartridge before disassembling it.
The “B” and “C” Cartridges can be disassembled by
removing the internal retaining ring. When operating
normally, the spool can be pushed in approximately
.070”. However, it is generally a better use of one’s
time to replace the cartridge. In the event jamming
or some other malfunction cannot be eliminated,
replace the cartridge since individual parts for it are
not available.
VALVE CARTRIDGE INFORMATION
-50-