DISASSEMBLY -ALL MODELS
FIGURE 3-2
To drain oil from the unit, remove the drain plug using a 1/4”
Allen wrench also remove pressure relief valve.
FIGURE 3-3
To remove motor, first remove the two phillip head screws
from the motor end cover.
For brush replacement see
Figures 3-87 and 3-88 (page 52).
FIGURE 3-4
To replace the motor remove the two cap screws, use a 3/8”
hex socket on the Fenner motor.
FIGURE 3-5
To replace the motor remove the two cap screws, use
a 10mm hex socket on the Iskra motor.
For brush
replacement see Figures 3-86 (page 52).