![Meyer E-60 QUIK-LIFT Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/meyer/e-60-quik-lift/e-60-quik-lift_service-manual_1781660035.webp)
FIGURE 3-18
Remove Pressure Port Filter and clean before reassembly.
DISASSEMBLY - ALL MODELS
FIGURE 3-19
Use a 1/2” Hex Socket remove retaining nut and then
remove “A” Coil from “A” Cartridge.
FIGURE 3-20
Remove “A” Cartridge using a 7/8” hex head deep
well socket
.
FIGURE 3-21
Remove “A” Cartridge from Sump Base.
-33-