DISASSEMBLY - ALL MODELS
FIGURE 3-15
Remove the Lower Adjusting Screw Cap Nut using a 11/16”
hex socket.
FIGURE 3-14
Remove Lower Filter and clean before reassembly.
FIGURE 3-16
Directly beneath the Cap Nut is the location of the Lower
Adjustment Screw. Remove the Lower Adjustment Screw
from the Sump Base using a 3/16” Allen wrench.
FIGURE 3-17
Remove Pressure Port Filter Cap Nut.