7 SG9H 70 en
23
8.1.2 Markings
The limit switch is provided with an identification plate, see
Fig. 32. Identification plate markings include:
Type designation
Electrical values
Temperature range
Enclosure class
Conduit entry
Manufacturing serial number
The type designation is described in Chapter 14.
8.1.3 Technical specifications
8.1.3.1 SG9_/D_
Proximity switch:
Inductive, Dual Module
2 sensors,
Normally Open
(33)
Normally Closed
(44)
Electrical values:
Metso SST Dual Module
(33)
Indications:
Target on sensor = LED on
Target off sensor = LED off
Operating voltage: 8–125 V DC; 24–125 V AC
Maximum voltage drop:
6.5 V/10 mA
7.0 V/100 mA
Current ratings:
Max inrush
2.0 A/125 V DC/V AC
Max continuous
0.3 A/125 V DC/V AC
Minimum on current 2.0 mA
Leakage current
< 0.15 mA with DC voltage
< 0.25 mA with AC voltage
Metso Dual Module
(44)
Indications:
Target on sensor = LED off
Target off sensor = LED on
Operating voltage: 6–29 V DC
Current ratings:
Target on (LED off ) < 1.0 mA
Target off (LED on) > 3.0 mA
Must use intrinsically safe repeater barrier.
Namur sensors conform to DIN 19234 standard.
Number of switches: 2
Ambient temperature: -40° to +80 °C / -40° to +176 °F
SIL:
Usable up to SIL3 acc. to IEC61508
8.1.3.2 SG9_H/R_
Reed switch type:
Maxx.Guard G, SPDT
(01)
Contact: Rhodium
Maxx.Guard H, SPDT
(04)
Contact: Rhodium
Topworx Go model 35
(35)
Contact: Silver cadmium
oxide, gold flashed
Electrical values:
300 mA: 24 V DC
(01)
200 mA: 125 V AC
I
max
3 A, V
max
240 V, W
max
100W
(04)
4 A: 120 V AC
(35)
3 A: 24 V DC
SIL:
Usable up to SIL3 acc. to IEC61508
Fig. 30
SG9_/K4_ layout
Fig. 31
VG9_/I57 and _/I58 layout.
Fig. 32
Example of identification plate
4 micro switches
terminals
M20 x 1.5
4 cams
ground
Содержание Switchguard SG9000H