8
7 SG9H 70 en
3.4
Mounting and installation of SG9300
Mounting bracket
Make sure the mounting bracket is suitable for the
weight of the device. See detailed weight informa-
tion in Section 1.5.
Three extra M8 mounting holes exist in the standard
mounting face of the housing for additional support. See
dimension drawings for SG9300 in pages 40-41 (Chapter
12). The use of this extra support is mandatory in addition
to the standard mounting face.
There are also two 6.5 mm holes for additional sup-
port when needed. See dimension drawings for
SG9300 in pages 40-41 (Chapter 12).
Pipeline support
Due to the extra weight of stainless steel version
and/or possible heavy vibration, make sure there are
proper supports in the pipeline to hold the weight of
the valve assembly.
Spool valve protective cover
The spool valve protective cover (454) has 2 pcs. of
1/2” NPT threaded openings.
Openings allow an adequate exhaust capacity and
breathing of the spool valve.
Openings have breathers (456) installed, but they
can be replaced with protective piping if needed
and when necessary.
If SG is installed vertically, it is recommended to
replace the breather with protective piping in the
opening pointing upwards.
Exhaust adapter
The exhaust adapter (8) has a 1/2” NPT threaded
opening.
Opening allows an excess air to be released from the
housing and to prevent overpressurization.
Exhaust adapter has a breather (456) installed, but it
can be replaced with protective piping if needed
and when necessary.
Opening in the exhaust adapter shall not be
plugged!
Protective piping
Piping of the spool valve cover and/or exhaust
adapter shall be done in cases where it is assumed
that water can go inside the spool valve cover or into
the exhaust adapter in spite of breathers.
Piping shall be done so that the blowing of the exhaust
air is downwards and to prevent water to go inside the
protective cover or the exhaust adapter.
Minimum inside diameter of the piping is 13 mm.
Exhaust adapter piping shall not be connected to
the spool valve cover piping!
NOTE:
These instructions are only for the mounting and installa-
tion of SG9300, i.e. stainless steel version of SG9000H.
Fig. 4
Shaft coupling alternatives
45°
45°
45°
45°
SG93
SG92
VDI/VDE 3845 mounting
IEC 60534 mounting
SHAFT ENDS
pointer
pointer
marks
on housing
marks
on housing