TROUBLESHOOTING CHAPTER
11
9
CRUSHER CONTROL
IN RUNNING MODE
Crusher stop request from
process ?
Clamping pressure not
between limits
Crusher drive pressure
probe failure
Crusher speed low
Main conveyor not
running
Crusher pressure high
Crusher running
Alarm 18, 19 or 21 Crusher stopping
Crusher not enable
Check main conveyor trip wire switches
reset if nesessary.
Check conveyors maintenance switch
position
Fault
Yes
Yes
Yes
Yes
Yes
Engine control
Crusher stopping
Yes
Alarm 4 or 5
Crusher stopping
Crusher not enable. Check charging circuit
operating charging valve manually.
!
does the pressure change
at UCD page 1.2
!
if not check sensor
Check HCM XM2 output 22 if on check
the voltage in the Danfoss valve plug if ok
the danfoss valve control head failured
Alarm 41
Crusher stopping
Crusher not enable
Check wiring if ok
Replace sensor
Alarm 8
Crusher stopping
Crusher not enable
Check crusher V-belt tension
Check used setting
!
open if nesessary
Check / adjust the crushing speed
!
Parameter C1
!
increase the mA value
Crusher should run 300 rpm (avg.) with the
material
Alarm 2
Crusher stopping
Crusher not enable
Check used setting
!
open if nesessary
Check / adjust the crushing speed
!
Parameter C1
!
increase the mA value
Crusher should run 300 rpm (avg.) with the
material
https://tractormanualz.com/
Содержание NORDBERG LT105
Страница 1: ...NORDBERG LT105 LT105S INSTRUCTION MANUAL 140561 B https tractormanualz com ...
Страница 82: ...9 10 NORDBERG LT105 105S INSTRUCTION MANUAL 9 07 B 05 01 CHAPTER 9 MAINTENANCE https tractormanualz com ...
Страница 123: ...https tractormanualz com ...
Страница 124: ...https tractormanualz com ...
Страница 125: ...https tractormanualz com ...
Страница 126: ...https tractormanualz com ...