TROUBLESHOOTING CHAPTER
11
15
FEEDER STOP
Device pump probe
failure
Device pump
pressure high ?
Fuel level below
alarm level ?
Feeder stop from
process
Feeder stop from
radio
Feeder stop from
service platform
Feeder
stopped
Feeder start from
process ?
Feeder power
OFF
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Second LT alarm
stop
Yes
Alarm 35
Check: sensor & wiring // HCM XM3
analog input 7 ( 4 – 20 mA = "ok" )
Replace sensor if nesessary
Alarm 40 Check the reason for high
pressure. Material leakage under the
conveyor. If hydraulic pto is "on" are
the hoses connected. If magnet selected
"on" is it running.
Alarm 10
Add fuel
Check fuel sensor operation & wiring