background image

Every product returned for refund/credit must be accompanied by a Return Material Authorization (RMA) number, obtained from 

our Order Entry Group at 1-800-648-7952 or 1-425-446-6945. 

Repair and calibration:  

To find the nearest  service center, go to 

www.flukebiomedical.com/service

 or 

 

In the U.S.A.: 

  Cleveland Calibration Lab 

  Tel: 1-800-850-4606 

  Email

[email protected]

 

 

  Everett Calibration Lab 

  Tel: 1-800-850-4606 

  Email

[email protected]

  

 

In Europe, Middle East, and Africa: 

  Eindhoven Calibration Lab 

  Tel: +31-402-675300 

  Email

[email protected]

 

 

In Asia: 

  Everett Calibration Lab 

  Tel: +425-446-6945 

  Email: [email protected] 

Certification 

This instrument was thoroughly tested and inspected. It was found to meet Fluke Biomedical’s manufacturing specifications when 

it was shipped from the factory. Calibration measurements are traceable to the National Institute of Standards and Technology 

(NIST). Devices for which there are no NIST calibration standards are measured against in-house performance standards using 

accepted test procedures. 

WARNING 

Unauthorized user modifications or application beyond the published specifications may result in electrical shock hazards or 

improper operation. Fluke Biomedical will not be responsible for any injuries sustained due to unauthorized equipment 

modifications. 

Restrictions and Liabilities 

Information in this document is subject to change and does not represent a commitment by Fluke Biomedical. Changes 

made to the information in this document will be incorporated in new editions of the publication. No responsibility is 

assumed by Fluke Biomedical for the use or reliability of software or equipment that is not supplied by Fluke 

Biomedical, or by its affiliated dealers. 

Manufacturing Location 

The daeg

 

is manufactured in Norway for Fluke Biomedical, Everett, WA, U.S.A. 

Содержание daeg SPO2

Страница 1: ...daeg SPO2 Simulator User Manual Version 1 15_2 Updated 22 01 2007...

Страница 2: ...SICAL DAMAGE CAUSED BY MISUSE OR PHYSICAL ABUSE IS NOT COVERED UNDER THE WARRANTY Items such as cables and nonserialized modules are not covered under this warranty Recalibration of instruments is not...

Страница 3: ...e g cables carrying cases auxiliary modules etc are not eligible for return or refund Only products returned within 90 days from the date of original purchase are eligible for refund credit In order...

Страница 4: ...Calibration measurements are traceable to the National Institute of Standards and Technology NIST Devices for which there are no NIST calibration standards are measured against in house performance st...

Страница 5: ...Table of Contents daeg Specifications 7 daeg Quick Start 9 Unit Setup 11 Operation 13 Troubleshooting 19...

Страница 6: ...www metron biomed com 6 This page was intentionally left blank...

Страница 7: ...curacy 2 1mV System rate accuracy 0 1 System time resolution 10 s 100 kHz maximum update rate ECG OUTPUT The data below is related to factory installed waveform types NORMAL ECG SINUS 30 300 BPM resol...

Страница 8: ...www metron biomed com 8 This page was intentionally left blank...

Страница 9: ...djust the active parameter using the yellow Up and Down arrow keys on the keypad then press enter to confirm the change 3 To change the simulation setting for oximeter model Make Ambient Light Pigment...

Страница 10: ...www metron biomed com 10 This page was intentionally left blank...

Страница 11: ...Refer to the diagram below when installing the batteries You will need to depress the tabs shown in the diagram below and remove the bottom dark gray piece of the chassis This will then expose the bat...

Страница 12: ...www metron biomed com 12 This page was intentionally left blank...

Страница 13: ...ing the F3 button The F2 button will move the cursor to the next parameter Using the Up and Down arrows will let you change the value of the selected parameter You will then need to press the yes ente...

Страница 14: ...e F2 button will move the cursor to the next parameter Using the Up and Down arrows will let you change the value of the selected parameter You will then need to press the yes enter button to accept t...

Страница 15: ...elect which test you wish to perform on the finger probe when you have the probe tester adaptor box attached Diode Test Pressing DIODE runs the test This test gives a descriptive message as to the con...

Страница 16: ...ort in that element A Middle line is normal operation A Low indicates an open circuit Since this is a continuously running test it lets you flex you cable to check for intermittent failures Sensitivit...

Страница 17: ...as follows Up and Down arrows control the cursor position yes enter increases the indicated value no clear decreases the selected value F1 decreases the selected SPO2 value F2 increases the selected S...

Страница 18: ...www metron biomed com 18 This page was intentionally left blank...

Страница 19: ...not match A Confirm that the Make is properly selected Confirm your selection by pressing the ENTER key after changing the value Q The monitor is not reading any values A Check all connections and ve...

Страница 20: ...www metron biomed com 20 This page was intentionally left blank...

Отзывы: