MetriCorr
VL100 & MasterLink Operation Manual
7 | 45
2.3
VL100 & MasterLink w/lithium battery
The Slimline VL100 measurement module is included in the same housing as the MasterLink. A lithium
battery is placed in the bottom half of the enclosure. All connectors are placed on the top of the module.
(No connectors or buttons on the bottom)
Figure 5. VL100 & MasterLink without battery, as shipped
The battery lifetime greatly depends on the
measurement campaign indicated in the battery
specifications.
Please contact MetriCorr if the Lithium battery
has to be replaced.
VL100
–
Battery specifications
Battery type
Lithium Thionyl
Capacity
26Ah @ 3.6V, 92Wh
Lifetime
+2 years @ 6 logs/hour, daily transmission
+3 years @ 1 log/hour, daily transmission
+3 years @ 6 logs/hour, weekly transmission
+10 years @ 1 log/hour, weekly transmission
Figure 6. VL100 & MasterLink,
compact version without
battery, connectors & control
A:
Antenna connection
B:
Status/control
button & LED indicator
D:
Pipe/structure
connection
E:
Reference
electrode
connection
C:
Power supply connector
(with protective cap)
Содержание Slimline MasterLink