background image

Thermal Imaging Camera

Installation Guide

LWIR

3- 2

Fig. 3-3

3)  Grip the rear section of the input connector 

and unscrew it from the Power Supply Unit 

(Fig. 3-3).

Fig. 3-4

Fig. 3-6

The connection terminals inside the input 

connector will now be revealed (Fig. 3-4).

4)  Unscrew the connector front section from 

the Power Supply Unit and disassemble 

the remaining parts of the connector.

5)  Slide the rear locking ring, gasket and 

shell body over the mains input cable.

6)  Strip back the mains cable wires to the 

appropriate lengths and connect them to 

the 

Input

 connector terminals (Fig. 3-5) 

as per the wiring schedule below:

Pin 1 = Live
Pin 2 = Neutral
Pin 3 = N/C
E = Earth

7)  The mains input cable connector is now 

ready for re-assembly and connection to 

the Power Supply Unit (Fig. 3-6).  Re-

assemble the mains input connector.

Fig. 3-5

Содержание LAND LWIR

Страница 1: ...g Wavelength Infrared Thermal Imaging Camera i Q U A L I T Y C U S T O M E R S O L U T I O N S LWIR THERMAL IMAGER INSTALLATION GUIDE PUBLICATION NO 814975 LANGUAGE ENGLISH ISSUE 1 DATE 07 DECEMBER 20...

Страница 2: ...sensitive devices Equipment Operation Use of this instrument in a manner not specified by AMETEK Land may be hazardous Read and understand the user documentation supplied before installing and operat...

Страница 3: ...r Repair If you need to return goods for repair please contact our Customer Service Department for details of the correct returns procedure Any item returned to AMETEK Land should be adequately packag...

Страница 4: ...agrams 4 0 5 Using the Web Server Interface 5 1 5 1 Connecting to the Web Server 5 1 5 2 About the Web Server Interface 5 3 5 3 About the Web Server Menu 5 4 5 4 Settings 5 4 5 5 Frame Settings 5 5 5...

Страница 5: ...oose a mounting location that permits easy access to the system components wherever possible as this will speed up any system maintenance and repair Ensure that the mounting locations chosen for the c...

Страница 6: ...cription Options Meaning LWIR Series Name LWIR Long wavelength infrared 640 Pixel Resolution 640 640 x 480 pixels 0 500C Temperature Range 0 500C 0 to 500 C 100 1000C 100 to 1000 C 50 Horizontal Field...

Страница 7: ...Compliance EMC EN 61326 1 Camera Supply and I O Digital Connections M12 X coded 8 way connector 10 100 1000 Ethernet IEEE 802 3 at PoE Analog Connections 8 pin Binder Connector 2 pins 12 24V DC Power...

Страница 8: ...Green Camera Temperature OK Yellow Flashing Camera Temperature Warning Red Camera Temperature Alarm Thermal Imaging PSU Module UL Approved Components Connections Power supply Gb Ethernet communicatio...

Страница 9: ...be powered by an alternative power supply via cable Part N 806032 or Part N 806033 See section 3 2 3 1 Connecting the mains input to the TRACO Power Supply Unit The TRACO Power Supply Unit is supplied...

Страница 10: ...ower Supply Unit and disassemble the remaining parts of the connector 5 Slide the rear locking ring gasket and shell body over the mains input cable 6 Strip back the mains cable wires to the appropria...

Страница 11: ...n Guide Fig 3 7 8 Attach the mains cable to the Input connector of the Power Supply Unit Fig 3 7 You can now connect the TRACO Power Supply Unit to the LWIR camera via Interface PCB Part N 807941 Refe...

Страница 12: ...STALLATION DIAGRAMS 4 Installation Guide 4 0 This section of the Installation Guide provides a series of simple installation diagrams covering the installation of the LWIR thermal camera and its mount...

Страница 13: ...o Scale 1 of 17 All Materials and Finishes to be RoHS Compliant to Directive 2011 65 EU EU 2015 863 Chemicals in breach of EU REACH or US TSCA limits in this product must be reported to Land Instrumen...

Страница 14: ...sdale 740 123 1 25 08 2021 Installation Drawings for LMIR MWIR 640 Imager System 0310 LWIR 640 Camera Accessories c L 2021 Desiign Engineering PROJECTION DRG Size Standard Assembly DOCUMENT TYPE A2 No...

Страница 15: ...EU REACH or US TSCA limits in this product must be reported to Land Instruments CONFORMS TO BS 8888 TOLERANCING ISO 8015 ISO 2768 RESPONSIBLE DEPT D Bramhall 71 2 8 155 6 1 441 17 4 168 6 6 170 6 7 89...

Страница 16: ...n to the flange on the purge Ensure the lens is located onto the recess face Fasten securely in place Assembly Instructions for Mounting Camera to Housing 1 Locate the M5 countersink screw to Camera C...

Страница 17: ...liant to Directive 2011 65 EU EU 2015 863 Chemicals in breach of EU REACH or US TSCA limits in this product must be reported to Land Instruments CONFORMS TO BS 8888 TOLERANCING ISO 8015 ISO 2768 RESPO...

Страница 18: ...mits in this product must be reported to Land Instruments CONFORMS TO BS 8888 TOLERANCING ISO 8015 ISO 2768 RESPONSIBLE DEPT D Bramhall 70 2 8 101 4 0 265 10 4 124 4 9 393 15 5 M6x1 6H 9 5 3 8 9 5 3 8...

Страница 19: ...PROJECTION DRG Size Standard Assembly DOCUMENT TYPE A2 Not to Scale 7 of 17 All Materials and Finishes to be RoHS Compliant to Directive 2011 65 EU EU 2015 863 Chemicals in breach of EU REACH or US T...

Страница 20: ...nd Finishes to be RoHS Compliant to Directive 2011 65 EU EU 2015 863 Chemicals in breach of EU REACH or US TSCA limits in this product must be reported to Land Instruments CONFORMS TO BS 8888 TOLERANC...

Страница 21: ...ess Imager Power Supply AC DC 120W 24VDC Traco Tex Power Supply Refer to Traco Instructions for Mounting and Safety Requirements 4 6 83 164 Customer Supplied 110 230V AC Cable 805755 AMPHENOL C016 20D...

Страница 22: ...ess Imager Power Supply AC DC 120W 24VDC Traco Tex Power Supply Refer to Traco Instructions for Mounting and Safety Requirements 4 6 164 83 807942 Din Rail Mounted Interface PCB Customer Supplied 110...

Страница 23: ...Std Temp M12 Ethernet X Coded Connector M12 Ethernet X Coded Connector Free Ends Wired in to Din Rail Connect to Internal M12 Socket or to RJ45 with Std Cables 813478 Thermal Imaging PSU Module UL App...

Страница 24: ...Ethernet X Coded Connector 813514 10m Imager Power I O Cable High Temperature 815071 25m Imager Power I O Cable High Temperature 814968 50m Imager Power I O Cable High temperature or 807950 5 m Image...

Страница 25: ...thernet Cable Entry Connect to Internal M12 Socket M12 Ethernet X Coded Connector 813514 10m Imager Power I O Cable High Temperature 815071 25m Imager Power I O Cable High Temperature 814968 50m Image...

Страница 26: ...om Ethernet Switch or Desktop PoE Straight to PC or Laptop 809294 5m M12 to RJ45 Cable Std Temp 814616 20m M12 to RJ45 Cable Std Temp 814617 50m M12 to RJ45 Cable Std Temp High temp M12 M12 variants c...

Страница 27: ...N PERMISSION OF DRG TITLE MATERIAL FINISH Created by Approved by DATE DRG No SURFACE FINISH ALL SHARP CORNERS REMOVED Technical reference SCALE LAND INSTRUMENTS INTERNATIONAL LTD DRONFIELD S18 1DJ C S...

Страница 28: ...LWIR 640 Camera Accessories c L 2021 Design Engineering PROJECTION DRG Size Standard Assembly DOCUMENT TYPE A2 Not to Scale 16 of 17 All Materials and Finishes to be RoHS Compliant to Directive 2011...

Страница 29: ...eb browsers are supported by the LWIR Web Server Google Chrome Microsoft Edge Mozilla Firefox Connection can be made either directly to the Ethernet port on the camera or via an Ethernet switch on the...

Страница 30: ...Select the Internet Protocol option and click on Properties 4 Select the Use the following IP address option and enter the values IP address 10 1 10 150 Subnet mask 255 255 0 0 the default IP address...

Страница 31: ...lettes available 8 Temperature measurement span user adjustable Upper and lower limits can be set to any points within measurement range of LWIR 9 Full screen ON OFF control 10 Save Camera Settings Al...

Страница 32: ...settings For more information see Sections 5 6 and 5 7 I O allows you to set up to three outputs or two outputs and one input For more information see Section 5 8 Information gives read only informati...

Страница 33: ...ssivity value where 4mA 0 10 and 20mA 1 00 For more information on Emissivity visit www ametek land com Background Temperature The temperature of the area surrounding an object being measured can have...

Страница 34: ...a heated chamber or furnace the temperature of the furnace wall will affect the reading You can use the Background Temperature setting to input this temperature value which will be taken into account...

Страница 35: ...ermal image click and drag the mouse pointer to create a rectangle in the location where you want the ROI to be The ROI details are updated to show the co ordinates and size of the ROI 3 To help see t...

Страница 36: ...covered by the ROI you can either select a Manual input and type in the required Emissivity value or set it via the slider or you can choose to have the Emissivity set via a 4 to 20mA current input mA...

Страница 37: ...a A typical I O interface is shown in Fig 5 3 Fig 5 3 Typical Web I O Interface The interface also shows the pin connections for the outputs inputs on the LWIR cable connector The following outputs in...

Страница 38: ...output if it goes outside the range 600 C to 750 C You can specify multiple triggers for the relay by simply clicking on the Add button For a relay output with multiple triggers if the Alarm logic co...

Страница 39: ...utput 3 the Relay settings are identical in operation to those of Output 2 The options available for the Command input Cmd In for Input Output 3 each relate to the LWIR Camera and are as follows NUC t...

Страница 40: ...e covers the entire temperature range of your LWIR Thermal Imaging Camera either 0 to 500 C or 100 to 1000 C However your application may have temperatures which are well within these lower and upper...

Страница 41: ...hermal imaging camera 5 11 2 Averager Refer to Fig 4 2 The Averager time function can be used to smooth the temperature output signal in relation to the temperature input The Averager response can be...

Страница 42: ...itching on OFF delay Time period between the temperature falling below the threshold level and the Peak Picker function switching off In Hold mode at the end of the OFF delay the temperature output va...

Страница 43: ...ction Refer to Fig 5 6 The Sample and Hold time function is useful especially for measuring intermittent processes e g items on a conveyor belt The presence of a hot object can be used to activate the...

Страница 44: ...il PSU Interface PCB and Ethernet Switch 815180 Desktop PoE Power Supply 805024 6 3 Power I O Cables Standard Temperature Cables Camera to DIN Rail PSU Connection PCB Thermal Imaging PSU Description P...

Страница 45: ...Part N 25m M12 to M12 communication cable 2 x Connectors Standard temperature 810794 50m M12 to M12 communication cable 2 x Connectors Standard temperature 810889 Camera to RJ45 Ethernet port Thermal...

Страница 46: ...Horizontal FOV 11 or 6 deg 813479 Industrial Mounting Splash protection plate Suitable for use with cameras with Horizontal FOV 50 or 28 deg 814876 LWIR 640 light housing with purge Light Housing Pro...

Страница 47: ......

Страница 48: ...to meet your unique applications Enhancing user skills by providing access to product and application experts AMETEK Land s global service network provides unparalleled after sales services to ensure...

Отзывы: