17. Guarantee, Service and maintenance
Guarantee period
The guarantee terms and conditions, which you can review in the first
pages of this manual, apply.
Guarantee claims for compressors are valid for 12 months. If required
yearly and possible 3000 or 1500 hours maintenances are done, the
guarantee period may be extended for an additional year, however
not more than 2 years. Therefore max. possible guarantee period is 36
months.
3
Service intervals
Compulsory maintenance rates have to be met precisely. The following
maintenance and inspections have to be done: yearly filter cartridge -
exchange („Filter cartridge - exchange kit“), the 3000 or 1500 hours
maintenance, depending on compressor versions, with the „3000 hours
kit + valve block (complete)“ or the „1500 hours kit 24/30 + valve block
(complete)“. The required inspections have to be registered inside this
METASYS manual on page 11. METASYS reserves to himself the right to
request those registrations to ascertain maintenance and inspection
rates.
Repair works that go beyond the normal maintenance may only be carried
out by a qualified technician or by the METSYS Technical Customer Service.
Use only the replacement parts permitted by the manufacturer and the
accessories intended for this purpose.
Please request by email to [email protected] the proper item numbers
for the „Filter cartridge - exchange kit“, the „3000 hours kit + valve block
(complete)“ or the „1500 hours kit 24/30 + valve block (complete)“. Please
provide the module number of the aggregate and the serial number of the
compressor, which have to be maintained.
Before any maintenance or repair work is carried out, the
compressor must be switched off and unplugged from the
mains supply, and that the air tank is unpressurised (check
the pressure gauge).
4
Draining off condensate water
Condensate must be drained off every day.
Check for condensate in the air receiver
Switch off the compressor and reduce pressure to 1 bar
Place a collection container under the air receiver
Open the drain valve until there is no more condensate water inside
the air receiver
Close the drain valve again
Guarantee, Service and maintenance
Practice personnel, technicians
Service intervals
WHAT
WHEN
WHO
Switch off the compressor
at the end of the use
daily
Practice
personnel
Drain off condensate water
daily
Practice
personnel
Exchange of the filters
with the „Filter cart-
ridge - exchange kit“
yearly
Technician
Safety valve check
yearly
Technician
Check tightness of joints
Overall device examination
yearly
Technician
META Air 24 / 30
(including Light versions):
„1500 hours kit 24/30 +
valve block (complete)“
after 1500 working
hours / or at least
every 2 years
Technician
META Air 150 - 1300
(including Light versions):
„3.000 h kit + valve
block (complete)“
after 3000 working
hours / or at least
every 3 years
Technician