CH pump standstill time from the
thermostat
When the temperature of the heated rooms is reached (the contact of
the room thermostat is open), the CH pump is stopped for the CH pump
standstill time from the thermostat, after which the
CH pump operation
time from the thermostat
is activated.
Note: The following conditions
must be met in order to stop the pump via the room thermostat:
Boiler room thermostat selection
≠ deactivated
Pump shut-off from thermostat
= YES
CH pump standstill time from the
thermostat
Min. HUW temperature
It requires a HUW sensor to be plugged in. This parameter can be used
for limitation of possibility to choose too low value of HUW set
temperature.
Max. HUW temperature
It requires a HUW sensor to be plugged in. This parameter decides on
which maximum temperature will the HUW tank be heated during
dropping down excessive heat in alarm states. It is a crucial parameter
because setting this for too high value can lead to the risk of users
scalding with utility water. On the other hand, too low value of this
parameter can lead to a situation, when during boiler overheating there
will be no possibility to drop down excessive heat into the HUW tank.
When projecting the HUW installation, there should be an assumption of
controller malfunction. This situation can lead to dangerous level of HUW
temperature, leading to user scalding. It is advised to use additional
security precautions in form of thermostatic values.
Boiler temperature increase from
HUW and Mixer
This parameter determines the increase of the set boiler temperature in
order to load the HUW tank, buffer, and the mixer circuit. The
temperature is only increased when there is a need to do so. When the
set temperature of the boiler is on a satisfactory level, the regulator will
not change it in order to load the HUW tank, buffer, or mixer circuit. The
increase of the set boiler temperature for the period of loading the HUW
tank is signalled with the letter “C” in the main window of the display.
HUW operation extension
Available after connecting a HUW sensor. When the HUW tank is fully
loaded and the HUW pump is switched off, the boiler may be in danger
of overheating. This occurs when the set HUW temperature is higher
than the set boiler temperature. The problem is particularly prominent
when the HUW pump works in “SUMMER” mode and the CH pump is
deactivated. In order to cool the boiler down, the HUW pump operation
can be extended by the
HUW operation time time
value.
Circulation pump standstill time
It is the time between periods of circulation pump operation and it is
defined by the parameter
circulation standstill time
(recommended
setting is between 15-40 min.) The circulation pump is operating in
cycles for the time of
circulation operation time
(recommended setting is
between 60 and 120s.)
Circulation pump pperation time
Exchanger
It comes only for hydraulic installations with heat exchanger between
open and closed circuit. Available options are:
YES (the boiler pump is operating constantly in short circuit boiler
– heat
exchanger, it is not excluded e.g. from “SUMMER” function or HUW
priority)
NO (standard operation of boiler pump)
15.4
BUFFER
Buffer settings
Activation
This parameter is used to turn on operation with the buffer. It is
available after connecting an additional B module and buffer
temperature sensors.
Loading start temperature
The parameter
Loading Start temperature
defines the upper buffer
temperature below which the process of buffer loading is being
started. This process will then be finish when the bottom buffer
temperature will reach defined temperature in the parameter
Loading
Loading stop temperature
Содержание ecoMAX860P2-T
Страница 2: ...2...
Страница 6: ......
Страница 7: ...REGULATOR INSTRUCTION MANUAL ecoMAX860P2 T...
Страница 19: ...19 CONTROLLER INSTALLATION AND SERVICE SETTINGS MANUAL ecoMAX860P2 T...
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ...Jacek Kucharewicz ul Sikorskiego 66 16 100 Sok ka Poland tel 48 85 711 94 54 www metalfachtg com pl...