7I76 46
REFERENCE INFORMATION
LBP
RPC COMMANDS
RPC commands allow previously stored sequences of read/write commands to be
executed with a single byte command. Up to 64 RPC’s may be stored. RPC write
commands may include data if desired, or the data may come from the serial data stream.
RPCs allow significant command compression which improves communication bandwidth.
When used with SSLBP, the 7I76s process data transfer uses an RPC for efficiency
LBP RPC COMMAND
1
0
RPC5
RPC4
RPC3
RPC2
RPC1
RPC0
Bit 7..6
CommandType: must be 10b to specify RPC
Bit 5..0
RPCNumber: Specifies RPC 0 through 63
In the 7I76 LBP implementation, RPCPitch is 0x8 bytes so each RPC command has
native size of 0x08 bytes and start 0x8 byte boundaries in the RPC table area. RPCs can
cross RPCPitch boundaries if larger than RPCPitch RPCs are needed. The stored RPC
commands consist of LBP headers and addresses, and possibly data if the command
header has the RID bit set. RPC command lists are terminated by a 0 byte.
The RPC table is accessed at addresses 0 through RPCSize-1 This means with a
RPCPitch of 0x8 bytes, RPC0 starts at 0x0000, RPC1 starts at 0x008, RPC2 starts at
0x0010 and so on.
Before RPC commands can be written to the RPC table,the RPCMEM access flag
must be set. The RPCMEM access flag must be clear for normal operation.