7I76 30
REFERENCE INFORMATION
SSLBP
DATA_TYPE
The DATA_TYPE field is a single byte field that specifies the data type of the
process data element. Data types are as follows:
NUMBER
DATA_TYPE
NOTE
0x00
PAD
To pad for byte alignment
0x01
BITS
Packed bits, LSB is BIT 0
0x02
UNSIGNED
Numeric unsigned
0x03
SIGNED
Numeric twos complement LSB first
0x04
NONVOL_UNSIGNED
Numeric unsigned
0x05
NONVOL_SIGNED
Numeric twos complement LSB first
0x06
STREAM
Continuous data stream
0x07
BOOLEAN
Any length non-zero = true
DATA_DIRECTION
The DATA_DIRECTION field is a single byte field that specifies the data direction.
Valid Data direction bytes are as follows:
0x00
INPUT
(Read from remote)
0x40
BI_DIRECTIONAL
(Read from and written to remote)
0X80
OUTPUT
(Written to remote)
PARAMETER_MIN
The PARAMETER_MIN field is a 32 bit IEEE-754 floating point number that
specifies the minimum value of the process data element. This is to allow the driver to
present data in engineering units. Not valid for non-numeric data types
PARAMETER_MAX
The PARAMETER_MAX field is a 32 bit IEEE-754 floating point number that
specifies the maximum value of the process data element. This is to allow the driver to
present data in engineering units. Not valid for non-numeric data types.