![Mesa 7I76 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/mesa/7i76/7i76_manual_1775153042.webp)
7I76 36
REFERENCE INFORMATION
SETUP START
When the FPGA is first configured or after a stop all command, all LBP
communication channels are idle. A SETUP START command first initializes and all local
communication, error and status parameters and begins to establish communications with
all remote LBP devices. Unlike the NORMAL START command, SETUP START does no
device specific setup but instead creates a pass-through access mode that allows the host
to read or write any remote LBP device parameter. This allows simple utilities to setup 7I76
volatile and non-volatile parameters, and allows the host to do process data discovery to
determine the input and output process data information from the remote device.
SETUP MODE OPERATION
In setup mode the SSLBP interface is used as a passthrough device to allow
reading and writing parameters to the remote LBP device.
REMOTE READ EXAMPLE:
For a remote word read, the sequence of operations is as follows:
1. Issue a STOPALL command (0x800), wait for COMMAND register clear to verify stop
command completion.
2. Issue a setup START command (0xFNN) with bitmask (NN) of channels to start
3. Wait for COMMAND register clear to verify start command completion. (may be many
mS)
4. Read data register to verify that all selected channels started (a 1 bit means a fault in
the channel that the bit represents)
5. Write LBP word read command (0x45) in the MSByte ORed with the parameter address
to the selected channels CS register. (0x4500PPPP)
6. Issue a DOIT Command
7. Wait for the command register to be clear
8. Check that the data register is clear, any set bits indicate an error
9. Read the returned data in the LS word of the selected channels Interface0 register
10. Repeat from step 5 for any additional remote data reads
Remote read byte, word, long and double are basically equivalent, the only
difference being the LBP command (0x44,0x45,0x46,0x47 respectively) and the size of the
data read from the interface register(s)
Содержание 7I76
Страница 1: ...7I76 STEP DIR PLUS I O DAUGHTERCARD V1 22 ...
Страница 2: ......
Страница 9: ...7I76 3 CONNECTORS 7I76 CONNECTOR LOCATIONS AND DEFAULT JUMPER POSITIONS ...
Страница 58: ...7I76 52 DRAWINGS ...