7I76 12
OPERATION
ENCODER INTERFACE
The 7I76 provide a one channel encoder interface with index. This is intended as
a spindle encoder but can be used for other purposes. The encoder input can be
programmed for differential or single ended encoders. The encoder interface also provides
short circuit protected 5V power to the encoder. When used with single ended encoders,
the ENCA+, ENCB+ and IDX+ signals are wired to the encoder and the ENCA-,ENCB-,
and IDX- terminal left unconnected.
SPINDLE INTERFACE
The 7I76 provides one analog output for spindle control. The analog output is a
isolated potentiometer replacement type device. It functions like a potentiometer with
SPINDLE + being one end of the potentiometer, SPINDLEOUT being the wiper and
SPINDLE- being the other end. The voltage on SPINDLEOUT can be set to any voltage
between SPINDLE- and . Polarity and voltage range must always be observed
for proper operation. The voltage supplied between and SPINDLE- must be
between 5VDC an 15VDC with S always being more positive than SPINDLE-.
Because the analog output is isolated, bipolar output is possible, for example with
connected to 5V and SPINDLE- connected to -5V, a +-5V analog output range
is created. In this case the spindle output must be offset so that 50% of full scale is output
when a 0V output is required. Note that if bipolar output is used, the output will be forced
to SPINDLE- at startup or when SPINENA is false.
SPINDLE ISOLATED OUTPUTS
The 7I76 provides 2 isolated outputs for use for spindle direction control, and
spindle enable. These outputs are OPTO coupler Darlington transistors. They are all
isolated from one another so can be used for pull up or pull-down individually. They will
switch a maximum of 50 mA at 0 to 100 VDC. The SPINENA output is special as it uses
the same signal that enables the analog output. When the analog output is enabled, the
SPINENA OPTO output is on.
STATUS LEDS
The 7I76 has two yellow status LEDs for power monitoring, CR1 and CR2. CR1 on
the top left side of the 7I76 monitors 5V power. CR2 on the top right side of the 7I76
monitors field power. Both LEDs must be illuminated for normal operation.