Test 16 - Coin Mechs Test
This allows the operator to test the coin mechs
without adding credits. When a coin is deposited the
coin song is played and the mech number is
displayed on the overhead, but no credits are added.
Clearing Books/Reset Mode
To clear books or reset default settings, an option
button is pressed along with the TEST button(s).
Both buttons must be pressed simultaneously. Refer
to the table below:
BUTTONS
RESULTS
Test + Double Out
Clears Current Books
Test + Masters Out
Clear Lifetime &
Current Books
Test + Team
Reset Factory Default
Settings
Test + Double In
Resets Happy Hour
Start/Stop Settings
NOTE: ADDITIONALLY, HOLDING IN THE PLAYER CHANGE
BUTTON WHEN POWERING UP THE GAME WILL
CLEAR ALL CREDITS AND COIN COUNTERS,
ABORT ANY ACTIVE GAMES AND RESET THE IDLE
MODE DISPLAY.
MAINTENANCE
Bulb Replacement
To replace the light bulbs for REMOVE DARTS and
THROW DARTS:
1. Unlock and open the target section door.
2. Locate the defective bulb.
3. Pull the bulb to remove it.
4. Replace with a GE #161 bulb.
To replace the light bulbs for the Push-button Switch
or Coin Lamp:
1. Unlock and open the control panel or coin mech
door.
2. Locate and remove the defective bulb.
3. Replace with a GE #161 BULB.
To replace the bulbs in the overhead display:
1. Loosen the 6 screws that secure the bezel to the
frame and slide it off the chassis.
2. Locate the defective bulb.
3. Pull the bulb to remove it.
4. Replace with a GE #79 bulb.
5. Replace the bezel and secure with screws.
Target Maintenance
Removing Broken Tips
Broken tips can sometimes be pushed into the cavity
behind a segment and cause the segment to stick. If
this happens you will have to remove the target
matrix switch assembly to remove the tip.
1. Open the target door section.
2. Carefully remove the backboard and clean out
all broken tips.
3. Reassemble the backboard assembly, making
sure the latches are secure.
Cleaning the Cabinet
The cabinet, Lexan display and front base panel
should all be cleaned with a damp cloth and mild
detergent. The Lexan can be cleaned with a solution
for Plexiglas or acrylic surfaces.
NOTE:
NEVER SUBMERGE THE TARGET OR SEGMENTS
IN WATER.