2019r0
Page 38 of 82
Mercury 2+ Operator Terminal User Manual
Transmission of messages in pointtopoint configuration is
immediate, i.e. at every key stroke, or promptly after a cardread.
The control codes and escape sequences described in this section
are available, with the exceptions noted.
Transmitted messages follow the format:
<STX> ADDR FUNC ID DATA DMY CSUM <ETX>
Point to Point
Transmission
Start Transmission (02
H
)
A two byte address field, as set up in Telemetry
Address with value 1 to 15. For multidrop mode see
page 40. This is always "01" in point to point mode.
Determines type of information being transmitted with
a single byte character. For messages transmitted from
the Mercury 2+ terminal this is always "D" (44
H
), and
"R" (52
H
) for messages received by the Mercury 2+
terminal.
Identifies source of data from a single byte:
"B" (42
H
) data from Wiegand Security Card swipe
"C" (43
H
) data from Proximity Card reading
"E" (45
H
) data from Digital Input read.
Other ID codes are available in Multidrop mode (see
page 40)
Information being sent from the identified source:
data from Security Card, encoded as hex ASCII, or
data for Digital Input reader as a single byte.
Single character, usually 00
H
but if this would result in
the following CSUM byte being a control character, the
DMY is set to 20
H
.
A single byte checksum character, which is the 7 bit
negated algebraic sum of all the characters in the string
from <STX> to DMY inclusive.
End Transmission character (03
H
) (see Table 4)
<STX>
ADDR
FUNC
ID
DATA
DMY
CSUM
<ETX>
Examples of messages are given in Appendix B.
Содержание 2+
Страница 1: ...Mercury 2 Mercury 2 Operator Terminal User Manual ...
Страница 2: ...2019r0 Page 2 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 4: ...2019r0 Page 4 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 6: ...2019r0 Page 6 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 8: ...2019r0 Page 8 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 10: ...2019r0 Page 10 of 82 Mercury 2 Operator Terminal User Manual Mercury 2 Terminal With Proximity Card Reader ...
Страница 14: ...2019r0 Page 14 of 82 Mercury 2 Operator Terminal User Manual Mounting the Mercury 2 Terminal ...
Страница 16: ...2019r0 Page 16 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 18: ...2019r0 Page 18 of 82 Mercury 2 Operator Terminal User Manual Fig 3 I S Interface Module ...
Страница 22: ...2019r0 Page 22 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 50: ...2019r0 Page 50 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 54: ...2019r0 Page 54 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 56: ...2019r0 Page 56 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 58: ...2019r0 Page 58 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 61: ...Mercury 2 Operator Terminal User Manual Page 61 of 82 2019r0 Fig 5 Signal Levels on Multi Drop RS485 Lines ...
Страница 62: ...2019r0 Page 62 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...