XM1640S  

ISDN Terminal  

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 
 

1. Connectors Top 

 
  

 

 

 

 

P1:   

 

RS-232 - Serial Interface 

Type:  

Serial 

V.24 

(EIA/TIA-232-E). 

Connector:  

D-SUB  9 female 

Pin designation: 

 

 
 
 
 
 
 
 

 

 

Switch over between RS232 and RS485: 

As default, the RS232 interface is enabled. The RS485 

interface will be enabled by placing a jumper (wire) 

between terminal 3 of P4 and GND (P4-2).  

P2:  

 

RS-422 / RS-485 Interface 

Type: 

 

2-wire, half-duplex, ¼ unit load. 

Isolation:   

3000 VDC (1 minute) 

Termination: 

390R / 390R / 220R 

Pin designation:

 

 

 
 
 

 
 

 

Bus Termination: 

Plugging in the jumpers J1,J2,J3 connects the bus with the 

resistors for bus termination. All three jumpers should be 

jointly plugged either in or out.  

 

Sending AT commands with RS-485: 
 

To allow sending of AT commands to a modem using the 

half-duplex RS-485 interface, the command line echo must 

be disabled in the modem using the ATE0 command. This 

task should be made, using the RS232 interface, prior to 

use the RS485 interface.  

 

 

2. Connectors Bottom 

 
 
 
 
 

 

 

 
 

P3: ISDN 

Interface 

Type: 

S-Bus    

Speed: 

1D+1B channel  

Isolation: 1500 

VDC 

Protection: Standard 

ESD 

 

Pin designation:  

 

 

 

 

 
 
 
 
 
 
 

P4: Power 

Supply 

Input voltage:  

9…32 V

DC  

Power input: 

100mA @ 9V

DC    

(average) 

120mA @ 9V

DC    

(peak) 

 

Pin designation: 

 

 

 

 

External Reset: 

Pin 4 provides an external Reset signal input. Leave open 

if not used. To activate the Reset input, simply connect it to 

ground (pin 2), using an external relay. After releasing the 

reset input, the modem starts up again.  

 

 

Do not connect the modem to the  

mains power directly.  

 

 

 

 

 

 

3. Front side 

 

Led indicators: 
 
 
 
 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

4. Operating conditions 

 

Environmental conditions: 

Operating temp. 

-20°C to +70°C  

Storage temp. 

-40°C to +85°C 

Rel. humidity: 

 75% acc. EN60068-2-30 

Protection type: 

IP50 acc. IEC529 

Vibration: acc. 

EN60068-2-6 

Shock : 

acc. EN60068-2-27 

Dimensions:

 

120 x 101 x 23 mm 

Mounting:

 

any direction 

 
 
ESD Protection: 

 

RS232 Interface:    +/- 15kV HBM

 

 

8kV IEC 61000-4-2

 

All other ports: 

+/- 15kV

 

 

IEC 61000-4-2, level 4

 

 

 

 

 

 

5. Operation 

 

The proper and safe operation of this device assumes that 

the operating instructions and the safety warnings given in  

this document are read carefully. 

 

Make sure that all cables are not live when making the 

connections! Impending danger by high input voltage or 

high power supply voltage! 

 

Electrical connections are observed. The device should 

only be handled by appropriately trained personnel who

 

 
 
 

xmodus swiss GmbH 

Dachslernstrasse 63 
CH – 8048 Zürich 
Phone +41 44 438 88 82 
Fax      +41 44 438 88 83 
e-mail:[email protected] 

http://www.xmodus.ch

 

 

Document-#:  XM1640S-E00-101 

 

1 DCD 
2 RXD 
3 TXD 
4 DTR 
5 GND 
6 DSR 
7 RTS 
8 CTS 
9 RI 

A - wire 

B - wire 

3 GND 

Signal 

4 GND 

Signal 

J1 390R 

(A) 

J2 220R 

(A-B) 

J3 390R 

(B) 

1 TX+ 
2 TX- 
3 RX+ 
4 RX- 

DC INPUT  

- GND 

S Enable 

RS485 

External  Reset 

ON Power 

On 

DCD Modem 

Connected 

TXD Transmitted 

Data 

RXD Received 

Data 

OPERATING INSTRUCTIONS 

P1 

P2

A    B    GND 

J1 J2 J3 

P3

P4

+   –     S     R

1     2     3    4