Mercury 2+ Operator Terminal User Manual
Page 41 of 82
2019r0
To select Graphics with Text or Graphics alone, see page 35. Note
that on Mercury terminals with text only, the enhanced software
described below is not available.
In Graphics mode, the display is made up of 64 rows of 40
columns. Each column position is a 'tile' made up of 6 pixels
across by 1 pixel in height.
No cursor is visible in graphics mode. As a tile is written, a virtual
cursor is incremented. The virtual cursor has its own set of
coordinates allowing access to graphics without corrupting text
currently displayed.
Coordinates are defined by the byte number and row number,
calculated from the top left corner of the display. With one byte
equating to 6 pixels, simple or bitmap images are positioned
horizontally from the 6 pixel boundaries.
Graphics may be downloaded as a bitmap image from offline
Graphics Converter Software, available from Mercury HMI Ltd, or
designed directly on the display.
Each tile is individually accessible, and each pixel pattern is
uniquely mapped to an ASCII character, defined in Table 7 below.
In the table a ○ represents a clear, OFF state pixel, and a ●
represents a pixel in the energised, ON state. The pixel pattern is
read left to right.
Graphics Display
Mode
Graphics Display
○○○○○○
○○○○○●
○○○○●○
○○○○●●
○○○●○○
○○○●○●
○○○●●○
○○○●●●
○○●○○○
○○●○○●
○○●○●○
○○●○●●
○○●●○○
○○●●○●
○○●●●○
○○●●●●
SP
!
“
#
$
%
&
‘
(
)
*
+
,
.
/
○●○○○○
○●○○○●
○●○○●○
○●○○●●
○●○●○○
○●○●○●
○●○●●○
○●○●●●
○●●○○○
○●●○○●
○●●○●○
○●●○●●
○●●●○○
○●●●○●
○●●●●○
○●●●●●
0
1
2
3
4
5
6
7
8
9
:
;
<
=
>
?
●○○○○○
●○○○○●
●○○○●○
●○○○●●
●○○●○○
●○○●○●
●○○●●○
●○○●●●
●○●○○○
●○●○○●
●○●○●○
●○●○●●
●○●●○○
●○●●○●
●○●●●○
●○●●●●
@
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
●●○○○○
●●○○○●
●●○○●○
●●○○●●
●●○●○○
●●○●○●
●●○●●○
●●○●●●
●●●○○○
●●●○○●
●●●○●○
●●●○●●
●●●●○○
●●●●○●
●●●●●○
●●●●●●
P
Q
R
S
T
U
V
W
X
Y
Z
[
\
]
^
_
Table 7
Graphics
Mode Pixel Data
Содержание 2+
Страница 1: ...Mercury 2 Mercury 2 Operator Terminal User Manual ...
Страница 2: ...2019r0 Page 2 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 4: ...2019r0 Page 4 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 6: ...2019r0 Page 6 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 8: ...2019r0 Page 8 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 10: ...2019r0 Page 10 of 82 Mercury 2 Operator Terminal User Manual Mercury 2 Terminal With Proximity Card Reader ...
Страница 14: ...2019r0 Page 14 of 82 Mercury 2 Operator Terminal User Manual Mounting the Mercury 2 Terminal ...
Страница 16: ...2019r0 Page 16 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 18: ...2019r0 Page 18 of 82 Mercury 2 Operator Terminal User Manual Fig 3 I S Interface Module ...
Страница 22: ...2019r0 Page 22 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 50: ...2019r0 Page 50 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 54: ...2019r0 Page 54 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 56: ...2019r0 Page 56 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 58: ...2019r0 Page 58 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...
Страница 61: ...Mercury 2 Operator Terminal User Manual Page 61 of 82 2019r0 Fig 5 Signal Levels on Multi Drop RS485 Lines ...
Страница 62: ...2019r0 Page 62 of 82 Mercury 2 Operator Terminal User Manual This page is intentionally left blank ...